Service Entrance Hosting Capacity
Abstract
A large share of DER, particularly residential solar photovoltaics systems, are being connected at the customer's service entrance. While extensive work has been performed to determine hosting capacity upstream of the distribution service transformer, less emphasis has been given on how to consider the impact when DER is interconnected downstream. This paper takes initial steps to determine service entrance hosting capacity. The hosting capacity of three real North American residential services is analyzed. The underlying sensitivities are examined in detail. Moreover, the impact of the individual customer load variability and split-phase transformer unbalance is studied.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The HC is higher with the shunt capacitor because the reactive power injected by the shunt capacitor lowers the bus voltages in the distribution network.
“They established that the HC is higher with the shunt capacitor.This is because the reactive power injected by the shunt capacitor lowers the bus voltages in the distribution network.”
From Methods and Tools for PV and EV Hosting Capacity Determination in Low Voltage Distribution Networks—A Review (2023) · cites this paper as [64]
Cited by
Sorted by citations
Umoh, V., Davidson, I., Adebiyi, A., & Ekpe, U. (2023) · Energies · doi:10.3390/en16083609 · Cited by 71 · see citing works
- Authors
- Peppanen, J., Bello, M., & Rylander, M.
- Affiliations
- Electric Power Research Institute (US)
- Venue
- 2018 IEEE 7th World Conference on Photovoltaic Energy Conversion (WCPEC) (A Joint Conference of 45th IEEE PVSC, 28th PVSEC & 34th EU PVSEC)
- Publisher
- IEEE
- Published
- 2018-06
- Pages
- 1451-1456
- OpenAlex
- W2902822198
- Cited by
- 5
- References
- 0
- Citations by year
- 2024: 1 · 2023: 2 · 2020: 1 · 2019: 1
- FWCI
- 0.80
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- World Conference on Photovoltaic Energy Conversion (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Optimal Power Flow Distribution
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Smart Grid Energy Management
- Physical Sciences › Engineering › Control and Systems Engineering › Thermal Analysis in Power Transmission
- Keywords
- hosting capacity, distributed energy resources, residential photovoltaic systems, load variation, sensitivity analysis
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review