A Review on Machine Learning for EEG Signal Processing in Bioengineering
The DOI matches its Crossref record; 69 of the 69 references it cites were found in a registry or an index.
Abstract
Electroencephalography (EEG) has been a staple method for identifying certain health conditions in patients since its discovery. Due to the many different types of classifiers available to use, the analysis methods are also equally numerous. In this review, we will be examining specifically machine learning methods that have been developed for EEG analysis with bioengineering applications. We reviewed literature from 1988 to 2018 to capture previous and current classification methods for EEG in multiple applications. From this information, we are able to determine the overall effectiveness of each machine learning method as well as the key characteristics. We have found that all the primary methods used in machine learning have been applied in some form in EEG classification. This ranges from Naive-Bayes to Decision Tree/Random Forest, to Support Vector Machine (SVM). Supervised learning methods are on average of higher accuracy than their unsupervised counterparts. This includes SVM and KNN. While each of the methods individually is limited in their accuracy in their respective applications, there is hope that the combination of methods when implemented properly has a higher overall classification accuracy. This paper provides a comprehensive overview of Machine Learning applications used in EEG analysis. It also gives an overview of each of the methods and general applications that each is best suited to.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Delorme, A., & Makeig, S. (2004) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2003.10.009 · Cited by 24,371 · cited 1×
“[22] Traditionally, Mohammad-Parsa Hosseini is with the Bioengineering Department, Santa Clara University, Santa Clara, CA 95053 USA and also with the AI Research, Silicon Valley, CA USA (e-mail: mhosseini@scu.edu).”
BackgroundData clustering: 50 years beyond K-means
Jain, A. K. (2010) · Pattern Recognition Letters · doi:10.1016/j.patrec.2009.09.011 · Cited by 9,368
Kingsford, C., & Salzberg, S. L. (2008) · Nature Biotechnology · doi:10.1038/nbt0908-1011 · Cited by 727
Combrisson, E., & Jerbi, K. (2015) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2015.01.010 · Cited by 599
Approximate Entropy-Based Epileptic EEG Detection Using Artificial Neural Networks
Srinivasan, V., Eswaran, C., & Sriraam, N. (2007) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2006.884369 · Cited by 591
Yu, W., Liu, T., Valdez, R., Gwinn, M., & Khoury, M. J. (2010) · BMC Medical Informatics and Decision Making · doi:10.1186/1472-6947-10-16 · Cited by 508
Alickovic, E., Kevric, J., & Subasi, A. (2018) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2017.07.022 · Cited by 407
Guo, L., Rivero, D., & Pazos, A. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.08.030 · Cited by 399
Measuring Mental Workload with EEG+fNIRS
Aghajani, H., Garbey, M., & Omurtag, A. (2017) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2017.00359 · Cited by 236
LMD Based Features for the Automatic Seizure Detection of EEG Signals Using SVM
Zhang, T., & Chen, W. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2611601 · Cited by 232
Cited by
A., S., & R., S. (2023) · Decision Analytics Journal · doi:10.1016/j.dajour.2023.100230 · Cited by 432
Chaddad, A., Wu, Y., Kateb, R., & Bouridane, A. (2023) · Sensors · doi:10.3390/s23146434 · Cited by 305
Graph-Based Deep Learning for Medical Diagnosis and Analysis: Past, Present and Future
Ahmedt-Aristizabal, D., Armin, M. A., Denman, S., Fookes, C., & Petersson, L. (2021) · Sensors · doi:10.3390/s21144758 · Cited by 272
Neural Decoding of EEG Signals with Machine Learning: A Systematic Review
Saeidi, M., Karwowski, W., Farahani, F. V., Fiok, K., Taiar, R., Hancock, P. A., & Al-Juaid, A. (2021) · Brain Sciences · doi:10.3390/brainsci11111525 · Cited by 258
A Survey of Generative Adversarial Networks for Synthesizing Structured Electronic Health Records
Ghosheh, G. O., Li, J., & Zhu, T. (2024) · ACM Computing Surveys · doi:10.1145/3636424 · Cited by 95
“Conservative privacy guarantees such as differential privacy are helpful but can have a high cost on the fidelity and utility aspects.”
BackgroundTowards a Machine Learning Driven Trust Management Heuristic for the Internet of Vehicles
Siddiqui, S. A., Mahmood, A., Sheng, Q. Z., Suzuki, H., & Ni, W. (2023) · Sensors · doi:10.3390/s23042325 · Cited by 15
Metadata
- Authors
- Hosseini, M.-P., Hosseini, A., & Ahi, K.
- Venue
- IEEE Reviews in Biomedical Engineering
- Published
- 2021
- Volume
- 14
- Pages
- 204-218
- ISSN
- 1937-3333 (ISSN-L)
- 1941-1189
- OpenAlex
- W3004161400
- Cited by
- 468
- References
- 69
- FWCI
- 20.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.