The DOI matches its Crossref record.
Design and development of an underactuated prosthetic hand
Abstract
Current prosthetic hands are basically simple grippers with one or two degrees of freedom, which barely restore the capability of the thumb-index pinch. Although most amputees consider this performance as acceptable for usual tasks, there is ample room for improvement by exploiting recent progresses in mechatronic design and technology. This paper focus on an innovative approach for the design and development of prosthetic hands based on underactuated mechanisms. Furthermore, it describes the development and a preliminary analysis of a first prototype of an underactuated prosthetic hand.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The SmartHand transradial prosthesis
Cipriani, C., Controzzi, M., & Carrozza, M. C. (2011) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-8-29 · Cited by 286
Self-citationThe SPRING Hand: Development of a Self-Adaptive Prosthesis for Restoring Natural Grasping
Carrozza, M. C., Suppo, C., Sebastiani, F., Massa, B., Vecchi, F., Lazzarini, R., Cutkosky, M. R., & Dario, P. (2004) · Autonomous Robots · doi:10.1023/b:auro.0000016863.48502.98 · Cited by 255
Self-citationO’Brien, K. W., Xu, A., Levine, D. J., Aubin, C. A., Yang, H.-J., Xiao, M. F., Wiesner, L. W., & Shepherd, R. F. (2018) · Science Robotics · doi:10.1126/scirobotics.aau5543 · Cited by 71
Design, control, and sensory feedback of externally powered hand prostheses: a literature review
Cloutier, A., & Yang, J. (2013) · Critical Reviews in Biomedical Engineering · doi:10.1615/critrevbiomedeng.2013007887 · Cited by 36
(2004) · TECNALIA Publications (Fundación TECNALIA Research & Innovation) · Cited by 13
Metadata
- Authors
- Massa, B., Roccella, S., Carrozza, M. C., & Dario, P.
- Venue
- Proceedings 2002 IEEE International Conference on Robotics and Automation (Cat. No.02CH37292)
- Publisher
- IEEE
- Published
- 2003-06-25
- Volume
- 4
- Pages
- 3374-3379
- ISSN
- 1050-4729 (ISSN-L)
- OpenAlex
- W2120353831
- Cited by
- 333
- References
- 0
- FWCI
- 19.75
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design and development of an underactuated prosthetic hand. https://app.cochat.ai/papers/10.1109/robot.2002.1014232
- The paper
- Massa, B., Roccella, S., Carrozza, M. C., & Dario, P. (2003). Design and development of an underactuated prosthetic hand. Proceedings 2002 IEEE International Conference on Robotics and Automation (Cat. No.02CH37292). https://doi.org/10.1109/robot.2002.1014232
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.