Design of all-accelerometer inertial measurement unit for tremor sensing in hand-held microsurgical instrument
Open accessAbstract
We present the design of an all-accelerometer inertial measurement unit (IMU). The IMU forms part of an intelligent hand-held microsurgical instrument that senses its own motion, distinguishes between hand tremor and intended motion, and compensates in real-time the erroneous motion. The new IMU design consists of three miniature dual-axis accelerometers, two of which are housed in a sensor suite at the distal end of the instrument handle, and one located at the proximal end close to the instrument tip. By taking the difference between the accelerometer readings, we decouple the inertial and gravitational accelerations from the rotation-induced (centripetal and tangential) accelerations, hence simplifies the kinematic computation of angular motions. We have shown that the error variance of the Euler orientation parameters /spl theta//sub x/, /spl theta//sub y/ and /spl theta//sub z/ is inversely proportional to the square of the distance between the three sensor locations. Comparing with a conventional three gyros and three accelerometers IMU, the proposed design reduces the standard deviation of the estimates of translational displacements by 29.3% in each principal axis and those of the Euler orientation parameters /spl theta//sub x/, /spl theta//sub y/ and /spl theta//sub z/ by 99.1%, 99.1% and 92.8% respectively.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Cites
Adaptive cancelling of physiological tremor for improved precision in microsurgery
Riviere, C. N., Rader, R. S., & Thakor, N. V. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.686791 · Cited by 260 · cited 1× · see citing works
“The filtering algorithms remove the intended motion, compensate for the phase shift due to analog and digital filters, and model and estimate the tremor based on a dynamic sinusoidal model [10].”
MethodSelf-citation
Flagged first, then by citations
Cited by
Sorted by citations
Nonlinear Regression Model of aLow-$g$ MEMS Accelerometer
Ang, W. T., Khosla, P. K., & Riviere, C. N. (2007) · IEEE Sensors Journal · doi:10.1109/jsen.2006.886995 · Cited by 100 · see citing works
Self-citationActive tremor compensation in microsurgery
Ang, W. T., Pradeep, P. K., & Riviere, C. N. (2005) · The 26th Annual International Conference of the IEEE Engineering in Medicine and Biology Society · doi:10.1109/iembs.2004.1403784 · Cited by 61 · see citing works
Self-citationA Quaternion Weighted Fourier Linear Combiner for Modeling Physiological Tremor
Adhikari, K., Tatinati, S., Ang, W. T., Veluvolu, K. C., & Nazarpour, K. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2016.2530564 · Cited by 48 · see citing works
Self-citation
- Authors
- Ang, W. T., Khosla, P. K., & Riviere, C. N.
- Affiliations
- Carnegie Mellon University (US)
- Venue
- 2003 IEEE International Conference on Robotics and Automation (Cat. No.03CH37422)
- Publisher
- IEEE
- Published
- 2004-03-01
- Pages
- 1781-1786
- ISSN
- 1050-4729 (ISSN-L)
- OpenAlex
- W2099345611
- Cited by
- 66
- References
- 1
- Citations by year
- 2023: 1 · 2022: 1 · 2020: 2 · 2019: 4 · 2017: 2 · 2016: 3 · 2014: 3 · 2013: 3 · 2012: 2
- FWCI
- 11.58
- Type
- conference paper
- Language
- en
- Open access
- green
- figshare.com
- Licence
- cc-by
- Locations
- Proceedings - IEEE International Conference on Robotics and Automation/Proceedings (publishedVersion)
- KiltHub Repository (submittedVersion)
- Figshare (submittedVersion, cc-by)
- KiltHub Repository
- Topics
- Physical Sciences › Engineering › Aerospace Engineering › Inertial Sensor and Navigation
- Physical Sciences › Engineering › Control and Systems Engineering › Robotic Mechanisms and Dynamics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced MEMS and NEMS Technologies
- Keywords
- inertial measurement unit, microsurgical instruments, tremor compensation, dual-axis accelerometer, sensor placement
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review