The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Development of a lightweight, underactuated exoskeleton for load-carrying augmentation
Abstract
Metabolic studies have shown that there is a metabolic cost associated with carrying load. Several leg exoskeletons have been developed by various groups in an attempt to augment the load carrying capability of the human. Previous research efforts have not fully exploited the passive dynamics of walking and have largely focused on fully actuated exoskeletons that are heavy with large energy requirements. In this paper, a lightweight, underactuated exoskeleton design is presented that runs in parallel to the human and supports the weight of a payload. Two exoskeleton architectures are pursued based on examining human walking data. A first architecture consists of springs at the hip, a variable impedance device at the knee, and springs at the ankle. A second architecture replaces the springs at the hip with a non-conservative actuator to examine the effect of adding power at desired instances throughout the gait cycle. Preliminary studies show that an efficient, underactuated leg exoskeleton can effectively transmit payload forces to the ground during the walking cycle
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
On the Biomimetic Design of the Berkeley Lower Extremity Exoskeleton (BLEEX)
Chu, A., Kazerooni, H., & Zoss, A. (2006) · Proceedings of the 2005 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2005.1570789 · Cited by 258 · cited 1×
“Several exoskeleton design approaches have employed hydraulic actuators to power hip, knee and ankle joints in the sagittal plane [4].”
Background
Cited by
Lower Extremity Exoskeletons and Active Orthoses: Challenges and State-of-the-Art
Dollar, A. M., & Herr, H. (2008) · IEEE Transactions on Robotics · doi:10.1109/tro.2008.915453 · Cited by 1,327
Self-citationRecent developments and challenges of lower extremity exoskeletons
Chen, B., Ma, H., Qin, L.-Y., Gao, F., Chan, K.-M., Law, S.-W., Qin, L., & Liao, W.-H. (2016) · Journal of Orthopaedic Translation · doi:10.1016/j.jot.2015.09.007 · Cited by 501
“…by Wehner et al [48] at Harvard University (Cambridge, MA, USA) to augment normal muscle function in healthy individuals; and an under-actuated leg exoskeleton for load-carrying augmentation was developed by the Massachusetts Institute of Technology Media Laboratory (Cambridge, MA, USA) [49,50].”
MethodExoskeletons and orthoses: classification, design challenges and future directions
Herr, H. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-21 · Cited by 477
Self-citationA QUASI-PASSIVE LEG EXOSKELETON FOR LOAD-CARRYING AUGMENTATION
WALSH, C. J., ENDO, K., & HERR, H. (2007) · International Journal of Humanoid Robotics · doi:10.1142/s0219843607001126 · Cited by 427
Self-citationAu, S., & Herr, H. (2008) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2008.927697 · Cited by 280
Self-citationOpportunities and challenges in the development of exoskeletons for locomotor assistance
Siviy, C., Baker, L. M., Quinlivan, B. T., Porciuncula, F., Swaminathan, K., Awad, L. N., & Walsh, C. J. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00984-1 · Cited by 258
Self-citation
Metadata
- Authors
- Walsh, C. J., Paluska, D., Pasch, K., Grand, W., Valiente, A., & Herr, H.
- Venue
- Proceedings 2006 IEEE International Conference on Robotics and Automation, 2006. ICRA 2006.
- Publisher
- IEEE
- Published
- 2006-07-10
- Pages
- 3485-3491
- ISSN
- 1050-4729 (ISSN-L)
- OpenAlex
- W2100030191
- Cited by
- 220
- References
- 1
- FWCI
- 12.82
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.