The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
ARMin II - 7 DoF rehabilitation robot: mechanics and kinematics
Abstract
Task-oriented repetitive movements can improve motor recovery in patients with neurological or orthopaedic lesions. The application of robotics can serve to assist, enhance, evaluate, and document neurological and orthopaedic rehabilitation. ARMin II is the second prototype of a robot for arm therapy applicable to the training of activities of daily living. ARMin II has a semi-exoskeletal structure with seven active degrees of freedom (two of them coupled), five adjustable segments to fit in with different patient sizes, and is equipped with position and force sensors. The mechanical structure, the actuators and the sensors of the robot are optimized for patient-cooperative control strategies based on impedance and admittance architectures. This paper describes the mechanical structure and kinematics of ARMin II.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lum, P. S., Burgar, C. G., Shor, P. C., Majmundar, M., & Van der Loos, M. (2002) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.33101 · Cited by 1,159 · cited 1×
“Several studies prove that arm therapy has positive effects on the rehabilitation progress of stroke patients (see [1], [2], [3], [4] and [5] for review).”
Background
Cited by
Timmermans, A. A., Seelen, H. A., Willmann, R. D., & Kingma, H. (2009) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-6-1 · Cited by 483
NEUROExos: a powered elbow exoskeleton for physical rehabilitation
Vitiello, N., Lenzi, T., Roccella, S., De Rossi, S. M. M., Cattin, E., Giovacchini, F., Vecchi, F., & Carrozza, M. C. (2013) · IEEE Transactions on Robotics · doi:10.1109/tro.2012.2211492 · Cited by 272
Connecting a Human Limb to an Exoskeleton
Jarrasse, N., & Morel, G. (2012) · IEEE Transactions on Robotics · doi:10.1109/tro.2011.2178151 · Cited by 263
Robots for Elderly Care in the Home: A Landscape Analysis and Co-Design Toolkit
Bardaro, G., Antonini, A., & Motta, E. (2022) · International Journal of Social Robotics · doi:10.1007/s12369-021-00816-3 · Cited by 92
Metadata
- Authors
- Mihelj, M., Nef, T., & Riener, R.
- Venue
- Proceedings 2007 IEEE International Conference on Robotics and Automation
- Publisher
- IEEE
- Published
- 2007-04
- Pages
- 4120-4125
- ISSN
- 1050-4729 (ISSN-L)
- OpenAlex
- W2112867487
- Cited by
- 215
- References
- 1
- FWCI
- 21.45
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: ARMin II - 7 DoF rehabilitation robot: mechanics and kinematics. https://app.cochat.ai/papers/10.1109/robot.2007.364112
- The paper
- Mihelj, M., Nef, T., & Riener, R. (2007). ARMin II - 7 DoF rehabilitation robot: mechanics and kinematics. Proceedings 2007 IEEE International Conference on Robotics and Automation. https://doi.org/10.1109/robot.2007.364112
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.