Analysis of the performance of IEEE 802.15.4 for medical sensor body area networking
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
For the first time, this paper presents an analysis of the performance of the IEEE 802.15.4 low power, low data rate wireless standard in relation to medical sensor body area networks. This is an emerging application of wireless sensor networking with particular performance constraints, including power consumption, physical size, robustness and security. In the analysis presented, the star network configuration of the 802.15.4 standard at 2.4 GHz was considered for a body area network consisting of a wearable or desk mounted coordinator outside of the body with up to 10 body implanted sensors. The main consideration in this work was the long-term power consumption of devices, since for practical reasons, implanted medical devices and sensors must function for at least 10 to 15 years without battery replacement. The results show that when properly configured, 802.15.4 can be used for medical sensor networking when configured in non-beacon mode with low data rate asymmetric traffic. Beacon mode may also be used, but with more severe restrictions on data rate and crystal tolerance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Telecommunication networks: protocols, modeling and analysis
Schwartz, M. (1986) · Addison-Wesley Longman Publishing Co., Inc. eBooks · Cited by 1,029
Radiowave propagation from a tissue-implanted source at 418 MHz and 916.5 MHz
Scanlon, W. G., Burns, B., & Evans, N. E. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.828152 · Cited by 164
Self-citation
Cited by
A survey on wireless body area networks
Latré, B., Braem, B., Moerman, I., Blondia, C., & Demeester, P. (2011) · Wireless Networks · doi:10.1007/s11276-010-0252-4 · Cited by 1,099
A Comprehensive Survey of Wireless Body Area Networks: On PHY, MAC, and Network Layers Solutions
Ullah, S., Higgins, H., Braem, B., Latre, B., Blondia, C., Moerman, I., Saleem, S., Rahman, Z., & Kwak, K. S. (2012) · Journal of Medical Systems · doi:10.1007/s10916-010-9571-3 · Cited by 811
“4 for low upload/download rates (mostly per hour) [31].”
BackgroundComparison of energy harvesting systems for wireless sensor networks
Gilbert, J. M., & Balouchi, F. (2008) · International Journal of Automation and Computing · doi:10.1007/s11633-008-0334-2 · Cited by 337
Implementation of wireless body area networks for healthcare systems
Yuce, M. R. (2010) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2010.06.004 · Cited by 331
The Age of Information in Multihop Networks
Bedewy, A. M., Sun, Y., & Shroff, N. B. (2019) · IEEE/ACM Transactions on Networking · doi:10.1109/tnet.2019.2915521 · Cited by 166
Metadata
- Authors
- Timmons, N. F., & Scanlon, W. G.
- Venue
- 2004 First Annual IEEE Communications Society Conference on Sensor and Ad Hoc Communications and Networks, 2004. IEEE SECON 2004.
- Publisher
- IEEE
- Published
- 2005-04-06
- Pages
- 16-24
- OpenAlex
- W2159389203
- Cited by
- 324
- References
- 2
- FWCI
- 65.23
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.