The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Novel fast voltage stability index (FVSI) for voltage stability analysis in power transmission system
Abstract
Since a couple of decades ago, voltage stability assessment has received increasing attention due to the complexity of power systems. With the increase in power demand and limited power sources has caused the system to operate at its maximum capacity. Therefore, a study that is able to determine the maximum capacity limit before voltage collapse must be carried out so that necessary precaution can be taken to avoid system capacity violation. This paper presents a novel fast voltage stability index (FVSI) simplified from a pre-developed voltage stability index referred to a line initiated from the voltage quadratic equation at the sending end of a representation of a 2-bus system. The line index in the interconnected system in which the value that is closed to 1.00 indicates that the line has reached its instability limit which could cause sudden voltage drop to the corresponding bus caused by the reactive load variation. The formulated index was tested on the IEEE reliability test system in order to verify the performance of the proposed indicator. Results showed that the proposed technique is indicative in predicting the occurrence of system collapse and hence necessary action can be taken to avoid such incident.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Voltage Stability of Electric Power Systems
Cutsem, T., & Vournas, C. (1998) · Springer eBooks · doi:10.1007/978-0-387-75536-6 · Cited by 2,036
Technique for contingency monitoring and voltage collapse prediction
Moghavvemi, M., & Omar, F. M. (1998) · IEE Proceedings - Generation, Transmission and Distribution · doi:10.1049/ip-gtd:19982355 · Cited by 321
Cited by
Ismail, B., Naain, M. M., Wahab, N. I. A., Awalin, L. J., Alhamrouni, I., & Rahim, M. F. A. (2017) · 2017 International Conference on Engineering Technology and Technopreneurship (ICE2T) · doi:10.1109/ice2t.2017.8215973 · Cited by 15
“The procedures to evaluate maximum loadability for strong and weak bus identification are determined as follows [10]:”
BackgroundMethodInfluentialVoltage stability indices studies on optimal location of wind farm in distribution network
Ismail, B., Naain, M. M., Wahab, N. I. A., Shaberon, N. S. M., Awalin, L. J., & Alhamrouni, I. (2017) · 2017 IEEE Conference on Energy Conversion (CENCON) · doi:10.1109/cencon.2017.8262468 · Cited by 12
Metadata
- Authors
- Musirin, I., & Abdul Rahman, T. K.
- Venue
- Student Conference on Research and Development
- Publisher
- IEEE
- Published
- 2003-06-25
- Pages
- 265-268
- OpenAlex
- W2169146929
- Cited by
- 307
- References
- 2
- FWCI
- 1.30
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Novel fast voltage stability index (FVSI) for voltage stability analysis in power transmission system. https://app.cochat.ai/papers/10.1109/scored.2002.1033108
- The paper
- Musirin, I., & Abdul Rahman, T. K. (2003). Novel fast voltage stability index (FVSI) for voltage stability analysis in power transmission system. Student Conference on Research and Development. https://doi.org/10.1109/scored.2002.1033108
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.