Who Controls the off Switch?
The DOI matches its Crossref record.
Abstract
We're about to acquire a significant new cyber- vulnerability. The world's energy utilities are starting to install hundreds of millions of 'smart meters' which contain a remote off switch. Its main purpose is to ensure that customers who default on their payments can be switched remotely to a prepay tariff; secondary purposes include supporting interruptible tariffs and implementing rolling power cuts at times of supply shortage. The off switch creates information security problems of a kind, and on a scale, that the energy companies have not had to face before. From the viewpoint of a cyber attacker - whether a hostile government agency, a terrorist organisation or even a militant environmental group - the ideal attack on a target country is to interrupt its citizens' electricity supply. This is the cyber equivalent of a nuclear strike; when electricity stops, then pretty soon everything else does too. Until now, the only plausible ways to do that involved attacks on critical generation, transmission and distribution assets, which are increasingly well defended. Smart meters change the game. The combination of commands that will cause meters to interrupt the supply, of applets and software upgrades that run in the meters, and of cryptographic keys that are used to authenticate these commands and software changes, create a new strategic vulnerability, which we discuss in this paper.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Smart Grid — The New and Improved Power Grid: A Survey
Fang, X., Misra, S., Xue, G., & Yang, D. (2012) · IEEE Communications Surveys & Tutorials · doi:10.1109/surv.2011.101911.00087 · Cited by 3,405
Cyber–Physical System Security for the Electric Power Grid
Sridhar, S., Hahn, A., & Govindarasu, M. (2012) · Proceedings of the IEEE · doi:10.1109/jproc.2011.2165269 · Cited by 1,208
Cyber-Physical Systems Security—A Survey
Humayed, A., Lin, J., Li, F., & Luo, B. (2017) · IEEE Internet of Things Journal · doi:10.1109/jiot.2017.2703172 · Cited by 1,185
Cyber Security and Privacy Issues in Smart Grids
Liu, J., Xiao, Y., Li, S., Liang, W., & Chen, C. L. P. (2012) · IEEE Communications Surveys & Tutorials · doi:10.1109/surv.2011.122111.00145 · Cited by 585
Differential Privacy Techniques for Cyber Physical Systems: A Survey
Hassan, M. U., Rehmani, M. H., & Chen, J. (2020) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2019.2944748 · Cited by 564
“Contrary to this, if any intruder gets the high resolution demand response data, then this data can be used for various monitoring and unethical purposes [180].”
Background
Metadata
- Authors
- Anderson, R., & Fuloria, S.
- Venue
- 2010 First IEEE International Conference on Smart Grid Communications
- Publisher
- IEEE
- Published
- 2010-10
- Pages
- 96-101
- OpenAlex
- W1971007446
- Cited by
- 117
- References
- 0
- FWCI
- 17.08
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Who Controls the off Switch? https://app.cochat.ai/papers/10.1109/smartgrid.2010.5622026
- The paper
- Anderson, R., & Fuloria, S. (2010). Who Controls the off Switch? 2010 First IEEE International Conference on Smart Grid Communications. https://doi.org/10.1109/smartgrid.2010.5622026
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.