Optimizing channel selection for seizure detection
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Interpretation of electroencephalogram (EEG) signals can be complicated by obfuscating artifacts. Artifact detection plays an important role in the observation and analysis of EEG signals. Spatial information contained in the placement of the electrodes can be exploited to accurately detect artifacts. However, when fewer electrodes are used, less spatial information is available, making it harder to detect artifacts. In this study, we investigate the performance of a deep learning algorithm, CNN-LSTM, on several channel configurations. Each configuration was designed to minimize the amount of spatial information lost compared to a standard 22-channel EEG. Systems using a reduced number of channels ranging from 8 to 20 achieved sensitivities between 33% and 37% with false alarms in the range of [38, 50] per 24 hours. False alarms increased dramatically (e.g., over 300 per 24 hours) when the number of channels was further reduced. Baseline performance of a system that used all 22 channels was 39% sensitivity with 23 false alarms. Since the 22-channel system was the only system that included referential channels, the rapid increase in the false alarm rate as the number of channels was reduced underscores the importance of retaining referential channels for artifact reduction. This cautionary result is important because one of the biggest differences between various types of EEGs administered is the type of referential channel used.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The temple university hospital EEG data corpus
Obeid, I., & Picone, J. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00196 · Cited by 528
Self-citation
Cited by
Deep learning-based electroencephalography analysis: a systematic review
Roy, Y., Banville, H., Albuquerque, I., Gramfort, A., Falk, T. H., & Faubert, J. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab260c · Cited by 1,532
Gu, X., Cao, Z., Jolfaei, A., Xu, P., Wu, D., Jung, T.-P., & Lin, C.-T. (2021) · IEEE/ACM Transactions on Computational Biology and Bioinformatics · doi:10.1109/tcbb.2021.3052811 · Cited by 395
A survey on deep learning-based non-invasive brain signals: recent advances and new frontiers
Zhang, X., Yao, L., Wang, X., Monaghan, J., McAlpine, D., & Zhang, Y. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abc902 · Cited by 296
Zeng, D., Huang, K., Xu, C., Shen, H., & Chen, Z. (2021) · IEEE Transactions on Cognitive and Developmental Systems · doi:10.1109/tcds.2020.3012278 · Cited by 74
IENet: a robust convolutional neural network for EEG based brain-computer interfaces
Du, Y., & Liu, J. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac7257 · Cited by 34
“Hybrid structures combine the advantages of different deep learning models and have performed well in multiple tasks such as epilepsy EEG detection [56], SSVEP classification [57], P300 visual-evoked potentials (EPs) detection [58] and motor imagery EEG classification [24, 27].”
Background
Metadata
- Authors
- Shah, V., Golmohammadi, M., Ziyabari, S., Von Weltin, E., Obeid, I., & Picone, J.
- Venue
- 2017 IEEE Signal Processing in Medicine and Biology Symposium (SPMB)
- Publisher
- IEEE
- Published
- 2017-12
- Pages
- 1-5
- ISSN
- 2372-7241 (ISSN-L)
- OpenAlex
- W2783428238
- Cited by
- 67
- References
- 1
- FWCI
- 6.78
- Type
- conference paper
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimizing channel selection for seizure detection. https://app.cochat.ai/papers/10.1109/spmb.2017.8257019
- The paper
- Shah, V., Golmohammadi, M., Ziyabari, S., Von Weltin, E., Obeid, I., & Picone, J. (2017). Optimizing channel selection for seizure detection. 2017 IEEE Signal Processing in Medicine and Biology Symposium (SPMB). https://doi.org/10.1109/spmb.2017.8257019
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.