Fault Estimation Sliding-Mode Observer With Digital Communication Constraints
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
This paper addresses the actuator fault estimation sliding-mode observer (SMO) design problem of linear continuous-time systems over digital communication channels. This problem frequently occurred in a network environment where data has to be quantized before being transmitted via digital communication channels. Traditional observers (linear Luenberger observer, Walcott–ZaK SMO) are not effective to solve this design issue since the effects of signal quantization will degrade estimation performances evidently. In this paper, a new descriptor SMO method is presented to overcome this difficult problem. It is shown that, if the quantizer density is larger than$\sqrt{2}-1$, the designed observer can compensate quantization errors completely, and the fault vector can be reconstructed despite of signal quantization. Finally, a simulation example with the F-404 aircraft engine model is proposed to demonstrate the effectiveness of the proposed robust digital observer design approach.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Control Under Communication Constraints
Tatikonda, S., & Mitter, S. K. (2004) · IEEE Transactions on Automatic Control · doi:10.1109/tac.2004.831187 · Cited by 1,667 · cited 1×
“We also point out that, such a transmission scheme was first presented in [16], where it is revealed that quantizing e1 (t) is more appropriate than quantizing y1 (t) to achieve ideal control system performances.”
BackgroundSliding mode observers for fault detection and isolation
Edwards, C., Spurgeon, S. K., & Patton, R. J. (2000) · Automatica · doi:10.1016/s0005-1098(99)00177-6 · Cited by 1,343
Fault Accommodation for Nonlinear Dynamic Systems
Jiang, B., Staroswiecki, M., & Cocquempot, V. (2006) · IEEE Transactions on Automatic Control · doi:10.1109/tac.2006.878732 · Cited by 781 · cited 1×
“2794826 technique, and sliding-mode observer (SMO) [8], [9], etc.”
State observation of nonlinear uncertain dynamical systems
Walcott, B. L., & Żak, S. H. (1987) · IEEE Transactions on Automatic Control · doi:10.1109/tac.1987.1104530 · Cited by 494 · cited 1×
“Walcott–Zak SMO Approach Second, we employ the classical Walcott–Zak SMO approach in [20] to revisit the numerical simulation.”
MethodLiu, M., & Shi, P. J. (2013) · Automatica · doi:10.1016/j.automatica.2013.01.030 · Cited by 351 · cited 1×
“The existing fault estimation approaches mainly include adaptive observer method [4]–[6], high gain observer approach [7], disturbance observer”
MethodSelf-citationShi, P., Liu, M., & Zhang, L. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2442221 · Cited by 316 · cited 1×
“Considering the F-404 aircraft engine model in [19] with”
MethodSelf-citationGao, Z., & Wang, H. (2005) · Systems & Control Letters · doi:10.1016/j.sysconle.2005.08.004 · Cited by 259 · cited 1×
“However, there exist two difficulties in this study: first, as mentioned in [14], the traditional linear Luenberger observer is not effective to eliminate output disturbances, since the output disturbances may be amplified when the observer gain matrix is of a high size; and second, the traditional SMO such as Walcott…”
BackgroundLiu, M., Ho, D. W. C., & Shi, P. (2015) · Automatica · doi:10.1016/j.automatica.2015.04.022 · Cited by 216
Self-citationSliding mode control for time-varying delayed systems based on a reduced-order observer
Yan, X., Spurgeon, S. K., & Edwards, C. (2010) · Automatica · doi:10.1016/j.automatica.2010.05.017 · Cited by 106 · cited 1×
“As mentioned in [18], ueq(t) can be approximated with any degree of accuracy by calculating (26) as us (t) = (α + φ) × (B (1) 1 ) T P1q(μ, s(t)) ‖(B((1)) 1 )T P1q(μ, s(t))‖ + ε1 (48)”
Sliding-Mode Filter Design for Linear Systems With Unmeasured States
Basin, M., & Rodríguez-Ramírez, P. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2081959 · Cited by 56
Cited by
Ma, H., Zhou, Q., Li, H., & Lu, R. (2022) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2021.3091531 · Cited by 318
Wang, H., Bai, W., Zhao, X., & Liu, P. X. (2022) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2020.3046316 · Cited by 306
A survey on sliding mode control for networked control systems
Hu, J., Zhang, H., Liu, H., & Yu, X. (2021) · International Journal of Systems Science · doi:10.1080/00207721.2021.1885082 · Cited by 280
Event-Based Formation Control for Nonlinear Multiagent Systems Under DoS Attacks
Tang, Y., Zhang, D., Shi, P., Zhang, W., & Qian, F. (2021) · IEEE Transactions on Automatic Control · doi:10.1109/tac.2020.2979936 · Cited by 267
Self-citationZhang, L., Liang, H., Sun, Y., & Ahn, C. K. (2021) · IEEE Transactions on Systems, Man, and Cybernetics: Systems · doi:10.1109/tsmc.2019.2912846 · Cited by 248
Self-citationNahian, S. A., Dinh, T. Q., Dao, H. V., & Ahn, K. K. (2020) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2020.3013609 · Cited by 29
“Remark 1: In contrast to the previous works [16] and [28], where convergence was studied with the expectation of fixed variances or output quantization errors, this article investigates the boundary of linearization error for any nonlinear systems while designing the sensor fault estimator.”
BackgroundResult
Metadata
- Authors
- Liu, M., Zhang, L., Shi, P., & Zhao, Y.
- Venue
- IEEE Transactions on Automatic Control
- Published
- 2018-10
- Volume
- 63
- Issue
- 10
- Pages
- 3434-3441
- ISSN
- 0018-9286 (ISSN-L)
- 1558-2523
- 2334-3303
- OpenAlex
- W2789389695
- Cited by
- 178
- References
- 10
- FWCI
- 11.79
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.