Design and Manufacturing of Stretchable High-Frequency Interconnects
The DOI matches its Crossref record.
Abstract
The increasing number of biomedical applications for electronic systems have led to the need for stretchable electronics in order to significantly enhance the comfort of the user. This paper describes the design and manufacturing process of new stretchable high-frequency interconnects with meander-shaped conductors in a coplanar waveguide topology. The novel interconnects are produced based on laser-ablation of a copper foil, which is then embedded in a highly stretchable bio-compatible silicone material. Measurements on prototypes of the designed stretchable high-frequency interconnects revealed a maximal magnitude of -14 dB for the reflection coefficient and a minimal magnitude of -4 dB for the transmission coefficient in the frequency band up to 3 GHz. The influence of stretch on the performance of the high-frequency interconnects was analyzed using a stretch testing machine. The results showed that nor the magnitude, neither the phase of the transmission coefficient was influenced by elongations up to 20%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Materials and Mechanics for Stretchable Electronics
Rogers, J. A., Someya, T., & Huang, Y. (2010) · Science · doi:10.1126/science.1182383 · Cited by 5,042
Wearable Electronics and Smart Textiles: A Critical Review
Stoppa, M., & Chiolerio, A. (2014) · Sensors · doi:10.3390/s140711957 · Cited by 2,107
“Usually, a polymeric material is chosen as encapsulating substrate, because it can be stretched and also because it may be bio-compatible [109].”
BackgroundFlexible Electronics: The Next Ubiquitous Platform
Nathan, A., Ahnood, A., Cole, M. T., Lee, S., Suzuki, Y., Hiralal, P., Bonaccorso, F., Hasan, T., Garcia-Gancedo, L., Dyadyusha, A., et al. (2012) · Proceedings of the IEEE · doi:10.1109/jproc.2012.2190168 · Cited by 1,000
Stretchable, Large‐area Organic Electronics
Sekitani, T., & Someya, T. (2010) · Advanced Materials · doi:10.1002/adma.200904054 · Cited by 842
Stretchable, Curvilinear Electronics Based on Inorganic Materials
Kim, D., Xiao, J., Song, J., Huang, Y., & Rogers, J. A. (2010) · Advanced Materials · doi:10.1002/adma.200902927 · Cited by 593
Reversibly Deformable and Mechanically Tunable Fluidic Antennas
So, J., Thelen, J., Qusba, A., Hayes, G. J., Lazzi, G., & Dickey, M. D. (2009) · Advanced Functional Materials · doi:10.1002/adfm.200900604 · Cited by 555
Directions Toward Effective Utilization of Tactile Skin: A Review
Dahiya, R. S., Mittendorfer, P., Valle, M., Cheng, G., & Lumelsky, V. J. (2013) · IEEE Sensors Journal · doi:10.1109/jsen.2013.2279056 · Cited by 428
Harris, K. D., Elias, A. L., & Chung, H.-J. (2016) · Journal of Materials Science · doi:10.1007/s10853-015-9643-3 · Cited by 403
“Reproduced with permission from [193] J Mater Sci (2016) 51:2771–2805 2787”
BackgroundMethodCheng, S., & Wu, Z. (2012) · Lab on a Chip · doi:10.1039/c2lc21176a · Cited by 300
Recent Advances in Stretchable and Transparent Electronic Materials
McCoul, D., Hu, W., Gao, M., Mehta, V., & Pei, Q. (2016) · Advanced Electronic Materials · doi:10.1002/aelm.201500407 · Cited by 293
Liquid metal stretchable unbalanced loop antenna
Cheng, S., Rydberg, A., Hjort, K., & Wu, Z. (2009) · Applied Physics Letters · doi:10.1063/1.3114381 · Cited by 245
Design and application of ‘J-shaped’ stress–strain behavior in stretchable electronics: a review
Ma, Y., Feng, X., Rogers, J. A., Huang, Y., & Zhang, Y. (2017) · Lab on a Chip · doi:10.1039/c7lc00289k · Cited by 211
Wang, X., Hu, H., Shen, Y., Zhou, X., & Zheng, Z. (2011) · Advanced Materials · doi:10.1002/adma.201101120 · Cited by 210
Screen-Printing Fabrication and Characterization of Stretchable Electronics
Suikkola, J., Björninen, T., Mosallaei, M., Kankkunen, T., Iso-Ketola, P., Ukkonen, L., Vanhala, J., & Mäntysalo, M. (2016) · Scientific Reports · doi:10.1038/srep25784 · Cited by 201
Materials for stretchable electronics in bioinspired and biointegrated devices
Kim, D.-H., Lu, N., Huang, Y., & Rogers, J. A. (2012) · MRS Bulletin · doi:10.1557/mrs.2012.36 · Cited by 198
Stretchable electronics: materials, architectures and integrations
Ahn, J.-H., & Je, J. H. (2012) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/45/10/103001 · Cited by 180
Microfluidic stretchable RF electronics
Cheng, S., & Wu, Z. (2010) · Lab on a Chip · doi:10.1039/c005159d · Cited by 177
Fabrication methods and applications of microstructured gallium based liquid metal alloys
Khondoker, M. A. H., & Sameoto, D. (2016) · Smart Materials and Structures · doi:10.1088/0964-1726/25/9/093001 · Cited by 170
“Among them, micro-sized helical wires [25], horseshoe like forms of gold [26] or copper [27], laser ablated copper foil in silicone [28], gold micro-wires with tortuosity [29], copper film by electroless deposition [30], meander-shaped nickel-gold layer in PDMS [31], and metal ion implanted elastomers [32], showed som…”
BackgroundShin, U.-H., Jeong, D.-W., Park, S.-M., Kim, S.-H., Lee, H. W., & Kim, J.-M. (2014) · Carbon · doi:10.1016/j.carbon.2014.08.079 · Cited by 163
“[5] Huyghe B, Rogier H, Vanfleteren J, Axia F.”
BackgroundPrintable stretchable interconnects
Dang, W., Vinciguerra, V., Lorenzelli, L., & Dahiya, R. (2017) · Flexible and Printed Electronics · doi:10.1088/2058-8585/aa5ab2 · Cited by 159
Metadata
- Authors
- Huyghe, B., Rogier, H., Vanfleteren, J., & Axisa, F.
- Venue
- IEEE Transactions on Advanced Packaging
- Published
- 2008-11
- Volume
- 31
- Issue
- 4
- Pages
- 802-808
- ISSN
- 1521-3323 (ISSN-L)
- 1557-9980
- OpenAlex
- W2110626201
- Cited by
- 97
- References
- 0
- FWCI
- 3.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.