The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Interface Design of a Physical Human–Robot Interaction System for Human Impedance Adaptive Skill Transfer
Abstract
It has been established that the transfer of human adaptive impedance is of great significance for physical human-robot interaction (pHRI). By processing the electromyography (EMG) signals collected from human muscles, the limb impedance could be extracted and transferred to robots. The existing impedance transfer interfaces rely only on visual feedback and, thus, may be insufficient for skill transfer in a sophisticated environment. In this paper, physical haptic feedback mechanism is introduced to result in muscle activity that would generate EMG signals in a natural manner, in order to achieve intuitive human impedance transfer through a designed coupling interface. Relevant processing methods are integrated into the system, including the spectral collaborative representation-based classifications method used for hand motion recognition; fast smooth envelop and dimensionality reduction algorithm for arm endpoint stiffness estimation. The tutor's arm endpoint motion trajectory is directly transferred to the robot by the designed coupling module without the restriction of hands. Haptic feedback is provided to the human tutor according to skill learning performance to enhance the teaching experience. The interface has been experimentally tested by a plugging-in task and a cutting task. Compared with the existing interfaces, the developed one has shown a better performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The central nervous system stabilizes unstable dynamics by learning optimal impedance
Burdet, E., Osu, R., Franklin, D. W., Milner, T. E., & Kawato, M. (2001) · Nature · doi:10.1038/35106566 · Cited by 1,097
Cited by
Cobot programming for collaborative industrial tasks: An overview
El Zaatari, S., Marei, M., Li, W., & Usman, Z. (2019) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2019.03.003 · Cited by 470
Bi, L., Feleke, A. >., & Guan, C. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.02.011 · Cited by 418
Yang, C., Jiang, Y., Na, J., Li, Z., Cheng, L., & Su, C.-Y. (2019) · IEEE Transactions on Fuzzy Systems · doi:10.1109/tfuzz.2018.2864940 · Cited by 334
Self-citation
Metadata
- Authors
- Yang, C., Zeng, C., Liang, P., Li, Z., Li, R., & Su, C.-Y.
- Venue
- IEEE Transactions on Automation Science and Engineering
- Published
- 2018-01
- Volume
- 15
- Issue
- 1
- Pages
- 329-340
- ISSN
- 1545-5955 (ISSN-L)
- 1558-3783
- OpenAlex
- W2754133402
- Cited by
- 224
- References
- 1
- FWCI
- 17.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Interface Design of a Physical Human–Robot Interaction System for Human Impedance Adaptive Skill Transfer. https://app.cochat.ai/papers/10.1109/tase.2017.2743000
- The paper
- Yang, C., Zeng, C., Liang, P., Li, Z., Li, R., & Su, C.-Y. (2018). Interface Design of a Physical Human–Robot Interaction System for Human Impedance Adaptive Skill Transfer. IEEE Transactions on Automation Science and Engineering. https://doi.org/10.1109/tase.2017.2743000
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.