The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
The Advanced Health and Disaster Aid Network: A Light-Weight Wireless Medical System for Triage
Abstract
Advances in semiconductor technology have resulted in the creation of miniature medical embedded systems that can wirelessly monitor the vital signs of patients. These lightweight medical systems can aid providers in large disasters who become overwhelmed with the large number of patients, limited resources, and insufficient information. In a mass casualty incident, small embedded medical systems facilitate patient care, resource allocation, and real-time communication in the advanced health and disaster aid network (AID-N). We present the design of electronic triage tags on lightweight, embedded systems with limited memory and computational power. These electronic triage tags use noninvasive, biomedical sensors (pulse oximeter, electrocardiogram, and blood pressure cuff) to continuously monitor the vital signs of a patient and deliver pertinent information to first responders. This electronic triage system facilitates the seamless collection and dissemination of data from the incident site to key members of the distributed emergency response community. The real-time collection of data through a mesh network in a mass casualty drill was shown to approximately triple the number of times patients that were triaged compared with the traditional paper triage system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
System architecture directions for networked sensors
Hill, J., Szewczyk, R., Woo, A., Hollar, S., Culler, D., & Pister, K. (2000) · ACM SIGPLAN Notices · doi:10.1145/356989.356998 · Cited by 3,084
System architecture directions for networked sensors
Hill, J. L., Szewczyk, R., Woo, A., Hollar, S., Culler, D., & Pister, K. S. J. (2000) · International Conference on Architectural Support for Programming Languages and Operating Systems (ASPLOS) · doi:10.1145/378993.379006 · Cited by 1,756
Sensor networks for medical care
Shnayder, V., Chen, B.-R., Lorincz, K., Jones, T. R. F. F., & Welsh, M. (2005) · Proceedings of the 3rd international conference on Embedded networked sensor systems · doi:10.1145/1098918.1098979 · Cited by 720
Self-citationAMON: A Wearable Multiparameter Medical Monitoring and Alert System
Anliker, U., Ward, J. A., Lukowicz, P., Troster, G., Dolveck, F., Baer, M., Keita, F., Schenker, E. B., Catarsi, F., Coluccini, L., et al. (2004) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2004.837888 · Cited by 707
Benson, M., Koenig, K. L., & Schultz, C. H. (1996) · Prehospital and Disaster Medicine · doi:10.1017/s1049023x0004276x · Cited by 400
A wireless PDA-based physiological monitoring system for patient transport
Lin, Y.-H., Jan, I.-C., Ko, P. C.-I., Chen, Y.-Y., Wong, J.-M., & Jan, G.-J. (2004) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2004.837829 · Cited by 348
MoteTrack: A Robust, Decentralized Approach to RF-Based Location Tracking
Lorincz, K., & Welsh, M. (2005) · Lecture Notes in Computer Science · doi:10.1007/11426646_7 · Cited by 271
Self-citationPrinciples and practice of emergency medicine
Schwartz, G. R. (1978) · Medical Entomology and Zoology · Cited by 184
Burkle, F. M. (2002) · Emergency Medicine Clinics of North America · doi:10.1016/s0733-8627(01)00008-6 · Cited by 113
Wireless technology and system integration in body area networks for M-health applications
Jovanov, E. (2005) · Cited by 96
Cited by
Wireless Body Area Networks: A Survey
Movassaghi, S., Abolhasan, M., Lipman, J., Smith, D., & Jamalipour, A. (2014) · IEEE Communications Surveys & Tutorials · doi:10.1109/surv.2013.121313.00064 · Cited by 1,538
Chen, M., Gonzalez, S., Vasilakos, A., Cao, H., & Leung, V. C. M. (2011) · Mobile Networks and Applications · doi:10.1007/s11036-010-0260-8 · Cited by 1,352
A Survey on Ambient Intelligence in Healthcare
Acampora, G., Cook, D. J., Rashidi, P., & Vasilakos, A. V. (2013) · Proceedings of the IEEE · doi:10.1109/jproc.2013.2262913 · Cited by 630
Enabling technologies for wireless body area networks: A survey and outlook
Cao, H., Leung, V., Chow, C., & Chan, H. (2009) · IEEE Communications Magazine · doi:10.1109/mcom.2009.5350373 · Cited by 518
Security Issues in Healthcare Applications Using Wireless Medical Sensor Networks: A Survey
Kumar, P., & Lee, H.-J. (2011) · Sensors · doi:10.3390/s120100055 · Cited by 413
Metadata
- Authors
- Gao, T., Massey, T., Selavo, L., Crawford, D., Chen, B.-R., Lorincz, K., Shnayder, V., Hauenstein, L., Dabiri, F., Jeng, J., Chanmugam, A., White, D., Sarrafzadeh, M., & Welsh, M.
- Venue
- IEEE Transactions on Biomedical Circuits and Systems
- Published
- 2007-09
- Volume
- 1
- Issue
- 3
- Pages
- 203-216
- ISSN
- 1932-4545 (ISSN-L)
- 1940-9990
- OpenAlex
- W2159470470
- Cited by
- 268
- References
- 15
- FWCI
- 18.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Advanced Health and Disaster Aid Network: A Light-Weight Wireless Medical System for Triage. https://app.cochat.ai/papers/10.1109/tbcas.2007.910901
- The paper
- Gao, T., Massey, T., Selavo, L., Crawford, D., Chen, B.-R., Lorincz, K., Shnayder, V., Hauenstein, L., Dabiri, F., Jeng, J., Chanmugam, A., White, D., Sarrafzadeh, M., & Welsh, M. (2007). The Advanced Health and Disaster Aid Network: A Light-Weight Wireless Medical System for Triage. IEEE Transactions on Biomedical Circuits and Systems. https://doi.org/10.1109/tbcas.2007.910901
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.