Systematic Design and Modeling of a OTA-C Filter for Portable ECG Detection
The DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
This study presents a systematic design of the fully differential operational transconductance amplifier-C (OTA-C) filter for a heart activities detection apparatus. Since the linearity and noise of the filter is dependent on the building cell, a precise behavioral model for the real OTA circuit is created. To reduce the influence of coefficient sensitivity and maintain an undistorted biosignal, a fifth-order ladder-type lowpass Butterworth is employed. Based on this topology, a chip fabricated in a 0.18- mum CMOS process is simulated and measured to validate the system estimation. Since the battery life and the integration with the low-voltage digital processor are the most critical requirement for the portable diagnosis device, the OTA-based circuit is operated in the subthreshold region to save power under the supply voltage of 1V. Measurement results show that this low-voltage and low-power filter possesses the HD3 of -48.9 dB, dynamic range (DR) of 50 dB, and power consumption of 453 nW. Therefore, the OTA-C filter can be adopted to eliminate the out-of-band interference of the electrocardiogram (ECG) whose signal bandwidth is located within 250 Hz.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Operation and modeling of the MOS transistor
Tsividis, Y. (1987) · Cited by 3,138
Medical Instrumentation-Application and Design
Webster, J. G. (1978) · Journal of Clinical Engineering · doi:10.1097/00004669-197807000-00017 · Cited by 1,847
The Biomedical Engineering Handbook
Bronzino, J. D., & Peterson, D. R. (2018) · CRC Press eBooks · doi:10.1201/b18423 · Cited by 1,599
Medical instrumentation: Application and design
Undar, A., Calhoon, J. H., & Rocha, A. D. (1997) · Control Engineering Practice · doi:10.1016/s0967-0661(97)90030-7 · Cited by 1,015
Design of analog integrated circuits and systems
(1995) · Choice Reviews Online · doi:10.5860/choice.32-2760 · Cited by 862
CMOS analog integrated circuits based on weak inversion operations
Vittoz, E., & Fellrath, J. (1977) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.1977.1050882 · Cited by 815 · cited 1×
“Note that has a typical value of 0.7 and is equal to , where is a slope factor [17], [ 18 ].”
BackgroundInfluentialA very low-power CMOS mixed-signal IC for implantable pacemaker applications
Wong, L. S. Y., Hossain, S., Ta, A., Edvinsson, J., Rivas, D. H., & Naas, H. (2004) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2004.837027 · Cited by 395
A CMOS analog front-end IC for portable EEG/ECG monitoring applications
Ng, K. A., & Chan, P. K. (2005) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2005.854141 · Cited by 229 · cited 1×
“On the other hand, since the biomedical monitoring system is often with a programmable low-noise instrumentation amplifier prior to the antialias filter [23], the amplitude of the weak bioelectric signal will be amplified to a higher level before further processing.”
BackgroundA 60-dB dynamic-range CMOS sixth-order 2.4-Hz low-pass filter for medical applications
Solis-Bustos, S., Silva-Martinez, J., Maloberti, F., & Sanchez-Sinencio, E. (2000) · IEEE Transactions on Circuits and Systems II: Analog and Digital Signal Processing · doi:10.1109/82.899631 · Cited by 227 · cited 2×
“Thus, there have been the proposal to use low-power continuous-time well-suited OTA-based filters composed of the open-loop OTA-C integrators [ 9 ]‐[13] in which the devices are operated in the subthreshold region to realize a very low transconductance ( , typically of the order of a few nanoamperes per volt).”
BackgroundMethodVeeravalli, A., Sanchez-Sinencio, E., & Silva-Martinez, J. (2002) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2002.1004582 · Cited by 176
The Biomedical Engineering Handbook: Second Edition.
W. von Maltzahn, W. (1999) · Electrical Engineering Handbook · doi:10.1201/9781420049510.sec8 · Cited by 170
A 1.25-V Micropower>tex<$G_m$>/tex<->tex<$C$>/tex
Rodriguez–Villegas, E., Yúfera, A., & Rueda, A. (2004) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2003.820848 · Cited by 71
A 1-/spl mu/A front end for pacemaker atrial sensing channels with early sensing capability
Lentola, L., Mozzi, A., Neviani, A., & Baschirotto, A. (2003) · IEEE Transactions on Circuits and Systems II Analog and Digital Signal Processing · doi:10.1109/tcsii.2003.813591 · Cited by 39 · cited 1×
“Switched-capacitor (SC) is a popular integrated circuit technique used in implementing this long-term ECG monitor system [ 6 ], [7].”
MethodEshraghian, K. (2006) · Proceedings of the IEEE · doi:10.1109/jproc.2006.873615 · Cited by 34
A very low power CMOS mixed-signal IC for implantable pacemaker applications
Wong, L. S. Y., Hossain, S., Ta, A., Weaver, L., Shaquer, G., Walker, A., Edvinsson, J., Rivas, D., Naas, H., Fawzi, A. H., et al. (2004) · Digest of technical papers/Digest of technical papers - IEEE International Solid-State Circuits Conference · doi:10.1109/isscc.2004.1332722 · Cited by 16
Metadata
- Authors
- Lee, S.-Y., & Cheng, C.-J.
- Venue
- IEEE Transactions on Biomedical Circuits and Systems
- Published
- 2009-02
- Volume
- 3
- Issue
- 1
- Pages
- 53-64
- ISSN
- 1932-4545 (ISSN-L)
- 1940-9990
- OpenAlex
- W2132978545
- Cited by
- 168
- References
- 15
- FWCI
- 4.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.