Cited by 241Wireless Power Transfer SystemsWireless Body Area NetworksNeuroscience and Neural Engineering

Modeling and optimization of printed spiral coils in air, saline, and muscle tissue environments

Open access
Uei-Ming Jow, Ghovanloo, M.·2009·IEEE Transactions on Biomedical Circuits and Systems

Abstract

Printed spiral coils (PSCs) are viable candidates for near-field wireless power transmission to the next generation of high-performance neuroprosthetic devices with extreme size constraints, which will target intraocular and intracranial spaces. Optimizing the PSC geometries to maximize the power transfer efficiency of the wireless link is imperative to reduce the size of the external energy source, heating of the tissue, and interference with other devices. Implantable devices need to be hermetically sealed in biocompatible materials and placed in a conductive environment with high permittivity (tissue), which can affect the PSC characteristics. We have constructed a detailed model that includes the effects of the surrounding environment on the PSC parasitic components and eventually on the power transfer efficiency. We have combined this model with an iterative design method that starts with a set of realistic design constraints and ends with the optimal PSC geometries. We applied our design methodology to optimize the wireless link of a 1-cm (2) implantable device example, operating at 13.56 MHz. Measurement results showed that optimized PSC pairs, coated with 0.3 mm of silicone, achieved 72.2%, 51.8%, and 30.8% efficiencies at a face-to-face relative distance of 10 mm in air, saline, and muscle, respectively. The PSC, which was optimized for air, could only bear 40.8% and 21.8% efficiencies in saline and muscle, respectively, showing that by including the PSC tissue environment in the design process the result can be more than a 9% improvement in the power transfer efficiency.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbcas.2009.2025366

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The implant's surrounding tissue significantly influences power transfer efficiency.

    “The study emphasized that the implant’s surrounding tissue significantly influences power transfer efficiency (Jow and Ghovanloo, 2009).”

    From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Jow and Ghovanloo, 2009

  • A study on Printed Spiral Coils optimized for a 10 mm face-to-face distance achieved efficiencies of 72.2% in air, 51.8% in saline, and 30.8% in muscle tissue.

    “For example a study on Printed Spiral Coils (PSCs) tailored for intracranial neuroprosthetics with PSCs optimized for a 10 mm face-to-face distance achieved varying efficiencies depending on the environment: 72.2% in air, 51.8% in saline, and 30.8% in muscle tissue.”

    From Comparative analysis of energy transfer mechanisms for neural implants (2024) · cites this paper as Jow and Ghovanloo, 2009

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 36 · Cited by 241

Research works printed but not linked: 29

  1. [3]Harrison RR Watkins PT Kier RJ Lovejoy RO Black DJ Greger B Solzbacher F Wireless neural recording with single low-power integrated circuit IEEE Trans. Neural Syst. Rehab. Eng to be published PMC2941647 19497825
  2. [4]sokal NO Sokal AD Class-E-A new class of high-efficiency tuned single-ended switching power amplifiers IEEE J. Solid-State Circuits Jun 1975 SSC-10 no. 3 168 176
  3. [5]Yang Z Liu W Basham E Inductor modeling in wireless links for implantable electronics IEEE Trans. Magn Oct 2007 43 no. 10 3851 3860
  4. [6]Shah MR Phillips RP Normann RA A study of printed spiral coils for neuroprosthetic transcranial telemetry applications IEEE Trans. Biomed. Eng Jul 1998 45 no. 7 867 876 9644895
  5. [7]Von Arx JA Najafi K A wireless single-chip telemetry-powered neural stimulation system Proc. IEEE Intl. Solid-State Circuits Conf. Digest Feb 1999 214 215
  6. [8]Töpper M Klein M Buschick K Glaw V Orth K Ehrmann O Hutter M Oppermann H Becker KF Braun T Ebling F Reichi H Kim S Tathireddy P Chakravarty S Solzbacher F Biocompatible hybrid flip chip microsystem integration for next generation wireless neural interfaces Proc. IEEE Elect. Components Tech. Conf May 2006 705 708
  7. [9]Kim S Zoschke K Klein M Black D Buschick K Toepper M Tathireddy P Harrison R Oppermann H Solzbacher F Switchable polymer-based thin film coils as a power module for wireless neural interfaces Sens. Actuators A Nov 2007 136 467 474 PMC2344127 18438447
  8. [10]Ko WH Liang SP Fung CDF Design of radio-frequency powered coils for implant instruments Med. Biol. Eng. Comput 1977 15 634 640 203785
  9. [11]Heetderks WJ RF powering of millimeter and submillimeter-sized neural prosthetic implants IEEE Trans. Biomed. Eng May 1988 35 no. 5 323 327 3397079
  10. [12]Zierhofer CM Hochmair ES Geometric approach for coupling enhancement of magnetically coupled coils IEEE Trans. Biomed. Eng Jul 1996 43 no. 7 708 714 9216142
  11. [14]Kendir GA Liu W Wang G Sivaprakasam M Bashirullah R Humayun MS Weiland JD An optimal design methodology for inductive power link with class-E amplifier IEEE Trans. Circuits Syst. I May 2005 52 no. 5 857 866
  12. [15]Baker MW Sarpeshkar R Feedback analysis and design of RF power links for low-power bionic systems IEEE Trans. Biomed. Circuits Syst Mar 2007 1 no. 1 28 38 23851518
  13. [16]Jow U Ghovanloo M Design and optimization of printed spiral coils for efficient transcutaneous inductive power transmission IEEE Trans. Biomed. Circuits Syst Sep 2007 1 no. 3 193 202 23852413
  14. [17]Finkenzeller K RFID Handbook: Fundamentals and Applications in Contactless Smart Cards and Identification 2003 Wiley Hoboken, NJ 2nd ed.
  15. [18]Mohan SS del Mar Hershenson M Boyd SP Lee TH Simple accurate expressions for planar spiral inductances IEEE J. Solid-State Circuits Oct 1999 34 no. 10 1419 1424
  16. [19]Pieters P Vaesen K Brebels S Mahmoud SF DeRaedt W Beyne E Mertens RP Accurate modeling of high-Q spiral inductors in thin-film multilayer technology for wireless telecommunication applications IEEE Trans. Microw. Theory Tech Apr 2001 49 no. 4, pt. 1 589 599
  17. [21]Gevorgian S Berg H Jacobsson H Lewin T Basic parameters of coplanar-strip waveguides on multilayer dielectric/semiconductor substrates, Part 1: High permittivity superstrates IEEE Microw. Mag Jun 2003 4 no. 2 60 70
  18. [22]Wheeler HA Formulas for the skin effect Proc. IRE Sep 1942 30, no. 9 412 424
  19. [23]Kuhn WB Ibrahim NM Analysis of current crowding effects in multiturn spiral inductors IEEE Trans. Microw. Theory Tech Jan 2001 49 no. 1 31 38
  20. [24]Ulrich RK Schaper LW ch. 11 Integrated Passive Component Technology 2003 Wiley Hoboken, NJ
  21. [25]Akyel C Babic S Kincic S New and fast procedures for calculating the mutual inductance of coaxial circular coils (circular coil-disk coil) IEEE Trans. Magn Sep 2002 38 no. 5 2367 2369
  22. [26]Gabriel S Lau RW Gabriel C The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz Phys. Med. Biol Nov 1996 41 2251 2269 8938025
  23. [27]Kim J Oh D Yoon J Cho S Kim N Cho J Kwon Y Cheon C Kim Y In vitro and in vivo measurement for biological applications using micromachined probe IEEE Trans. Microw. Theory Tech Nov 2005 53 no. 11 3415 3421
  24. [28]Jow U Ghovanloo M Optimization of a multiband wireless link for neuroprosthetic implantable devices Proc. IEEE Biomed. Circuits Syst Nov 2008 97 100 PMC3171452 21918679
  25. [29]Pozar DM ch. 4 Microw. Eng 1998 2nd ed. Wiley New York
  26. [30]Lazzi G Thermal effects of bioimplants Proc. IEEE Eng. Med. Biol. Mag Sep 2005 24 no. 5 75 81 16248120
  27. [31]Ghovanloo M Lazzi G Akay M Transcutaneous magnetic coupling of power and data Wiley Encyclopedia of Biomedical Engineering 2006 Wiley Hoboken, NJ
  28. [32]Ghovanloo M Atluri S A wideband power-efficient inductive wireless link for implantable microelectronic devices using multiple carriers IEEE Trans. Circuits Syst. I, Reg. Papers Oct 2007 54 no. 10 2211 2221
  29. [33]Bahl IJ Garg R Simple and accurate formulas for a microstrip with finite strip thickness Proc. IEEE Nov 1977 65 no. 11 1611 1612

Authors
Jow, U.-M., & Ghovanloo, M.
Affiliations
Georgia Institute of Technology (US)
Venue
IEEE Transactions on Biomedical Circuits and Systems
Published
2009-10
Volume
3
Issue
5
Pages
339-347
ISSN
  • 1932-4545 (ISSN-L)
  • 1940-9990
OpenAlex
W2147761718
Cited by
241
References
36
Citations by year
2026: 2 · 2025: 12 · 2024: 10 · 2023: 11 · 2022: 13 · 2021: 18 · 2020: 22 · 2019: 20 · 2018: 15 · 2017: 18 · 2016: 22 · 2015: 13 · 2014: 14 · 2013: 5 · 2012: 24
FWCI
12.17
Type
journal article
Language
en
Open access
Locations
  • IEEE Transactions on Biomedical Circuits and Systems (publishedVersion)
  • PubMed (publishedVersion)
  • Europe PMC (PubMed Central) (acceptedVersion)
  • PubMed Central (acceptedVersion)
Funders
  • Georgia Institute of Technology
  • Industrial Technology Research Institute
  • Tatung University
  • National Taiwan University
  • National Institute of Neurological Disorders and Stroke (R01NS062031)
  • National Institute of Biomedical Imaging and Bioengineering (R21EB009437)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Wireless Power Transfer Systems
  • Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
Keywords
near-field power transfer, power transfer efficiency, neuroprosthetics, biomedical implants, tissue permittivity, saline, muscle tissue, 13.56 MHz, iterative design optimization, parasitic components, silicone coating, hermetic sealing

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review