The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Low-Complexity Seizure Prediction From iEEG/sEEG Using Spectral Power and Ratios of Spectral Power
Abstract
Prediction of seizures is a difficult problem as the EEG patterns are not wide-sense stationary and change from seizure to seizure, electrode to electrode, and from patient to patient. This paper presents a novel patient-specific algorithm for prediction of seizures in epileptic patients from either one or two single-channel or bipolar channel intra-cranial or scalp electroencephalogram (EEG) recordings with low hardware complexity. Spectral power features are extracted and their ratios are computed. For each channel, a total of 44 features including 8 absolute spectral powers, 8 relative spectral powers and 28 spectral power ratios are extracted every two seconds using a 4-second window with a 50% overlap. These features are then ranked and selected in a patient-specific manner using a two-step feature selection. Selected features are further processed by a second-order Kalman filter and then input to a linear support vector machine (SVM) classifier. The algorithm is tested on the intra-cranial EEG (iEEG) from the Freiburg database and scalp EEG (sEEG) from the MIT Physionet database. The Freiburg database contains 80 seizures among 18 patients in 427 hours of recordings. The MIT EEG database contains 78 seizures from 17 children in 647 hours of recordings. It is shown that the proposed algorithm can achieve a sensitivity of 100% and an average false positive rate (FPR) of 0.0324 per hour for the iEEG (Freiburg) database and a sensitivity of 98.68% and an average FPR of 0.0465 per hour for the sEEG (MIT) database. These results are obtained with leave-one-out cross-validation where the seizure being tested is always left out from the training set. The proposed algorithm also has a low complexity as the spectral powers can be computed using FFT. The area and power consumption of the proposed linear SVM are 2 to 3 orders of magnitude less than a radial basis function kernel SVM (RBF-SVM) classifier. Furthermore, the total energy consumption of a system using linear SVM is reduced by 8% to 23% compared to system using RBF-SVM.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cortes, C., & Vapnik, V. (1995) · Machine Learning · doi:10.1007/bf00994018 · Cited by 59,421
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
Seizure detection, seizure prediction, and closed-loop warning systems in epilepsy
Ramgopal, S., Thome-Souza, S., Jackson, M., Kadish, N. E., Sánchez Fernández, I., Klehm, J., Bosl, W., Reinsberger, C., Schachter, S., & Loddenkemper, T. (2014) · Epilepsy & Behavior · doi:10.1016/j.yebeh.2014.06.023 · Cited by 469
Cited by
Truong, N. D., Nguyen, A. D., Kuhlmann, L., Bonyadi, M. R., Yang, J., Ippolito, S., & Kavehei, O. (2018) · Neural Networks · doi:10.1016/j.neunet.2018.04.018 · Cited by 635
Tsiouris, Κ. Μ., Pezoulas, V. C., Zervakis, M., Konitsiotis, S., Koutsouris, D. D., & Fotiadis, D. I. (2018) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2018.05.019 · Cited by 632
Epileptic Seizure Detection Based on EEG Signals and CNN
Zhou, M., Tian, C., Cao, R., Wang, B., Niu, Y., Hu, T., Guo, H., & Xiang, J. (2018) · Frontiers in Neuroinformatics · doi:10.3389/fninf.2018.00095 · Cited by 483
Efficient Epileptic Seizure Prediction Based on Deep Learning
Daoud, H., & Bayoumi, M. A. (2019) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2019.2929053 · Cited by 483
Classification using hyperdimensional computing: a review
Ge, L., & Parhi, K. K. (2020) · IEEE Circuits and Systems Magazine · doi:10.1109/mcas.2020.2988388 · Cited by 227
Self-citation
Metadata
- Authors
- Zhang, Z., & Parhi, K. K.
- Venue
- IEEE Transactions on Biomedical Circuits and Systems
- Published
- 2016-06
- Volume
- 10
- Issue
- 3
- Pages
- 693-706
- ISSN
- 1932-4545 (ISSN-L)
- 1940-9990
- OpenAlex
- W2291197622
- Cited by
- 228
- References
- 3
- FWCI
- 7.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Low-Complexity Seizure Prediction From iEEG/sEEG Using Spectral Power and Ratios of Spectral Power. https://app.cochat.ai/papers/10.1109/tbcas.2015.2477264
- The paper
- Zhang, Z., & Parhi, K. K. (2016). Low-Complexity Seizure Prediction From iEEG/sEEG Using Spectral Power and Ratios of Spectral Power. IEEE Transactions on Biomedical Circuits and Systems. https://doi.org/10.1109/tbcas.2015.2477264
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.