The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Spatial and Dynamic Aspects of Visual Fixation
Abstract
The physiological processes concerned with the difficult dynamic task of fixating the retinal image during normal body and head movement are examined with a control engineering perspective. Spatial relationships between the two main system inputs (visual and vestibular) and three main outputs (operating on the eye-in-skull, skull-on-body, and body-in-space platforms) are examined in the context of the geometry of the environment with the aid of an information flow diagram. From dynamic considerations a picture emerges in which the visual tracking system has adequate accuracy and dynamic range for following most naturally moving objects when the head is still. But with head free, the added perturbations of natural movement exceed these tracking capabilities. However, over the frequency range 0.1-5.0 c/s the semicircular canal subsystem then provides angular velocity information for powerful complementary servostabilization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The mechanics of human saccadic eye movement
Robinson, D. A. (1964) · The Journal of Physiology · doi:10.1113/jphysiol.1964.sp007485 · Cited by 893
Cited by
Separate body- and world-referenced representations of visual space in parietal cortex
Snyder, L. H., Grieve, K. L., Brotchie, P., & Andersen, R. A. (1998) · Nature · doi:10.1038/29777 · Cited by 507
Models of the saccadic eye movement control system
Robinson, D. A. (1973) · Kybernetik · doi:10.1007/bf00288906 · Cited by 502
Psychophysics of Vestibular Sensation
Guedry, F. E. (1974) · Handbook of Sensory Physiology · doi:10.1007/978-3-642-65920-1_1 · Cited by 425
A Systems Concept of the Vestibular Organs
Mayne, R. (1974) · Handbook of Sensory Physiology · doi:10.1007/978-3-642-65920-1_14 · Cited by 331
The Head-Neck Sensory Motor System
(1992) · doi:10.1093/acprof:oso/9780195068207.001.0001 · Cited by 331
Metadata
- Authors
- Jones, G. M., & Milsum, J. H.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1965-04
- Volume
- BME-12
- Issue
- 2
- Pages
- 54-62
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2111952723
- Cited by
- 207
- References
- 1
- FWCI
- 7.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Spatial and Dynamic Aspects of Visual Fixation. https://app.cochat.ai/papers/10.1109/tbme.1965.4502350
- The paper
- Jones, G. M., & Milsum, J. H. (1965). Spatial and Dynamic Aspects of Visual Fixation. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.1965.4502350
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.