The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
An Application of Signal Processing Techniques to the Study of Myoelectric Signals
Abstract
This paper describes the use of power spectral density and cumulative power functions in the examination of the electromyogram (EMG). The EMG signals were obtained with surface electrodes from two muscles, the flexor pollicis brevis and the extensor digitorum, in four subjects. Each muscle was studied at two levels of contraction, both before and during fatigue. The power spectral density functions are compared, using a cumulative power difference function and the mean frequency of the spectrum, to determine differences between loading conditions in an individual muscle, before and during fatigue, between different muscles, between individuals (same muscle), and combinations of these conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measurement and Analysis of Random Data
Jackson, R. (1967) · Physics Bulletin · doi:10.1088/0031-9112/18/7/023 · Cited by 783
de Alencar, M. S. (2022) · River Publishers eBooks · doi:10.1201/9781003338864-2 · Cited by 155
THE USE OF MYO-ELECTRIC CURRENTS IN THE OPERATION OF PROSTHESES
Battye, C. K., Nightingale, A., & Whillis, J. (1955) · Journal of Bone and Joint Surgery - British Volume · doi:10.1302/0301-620x.37b3.506 · Cited by 130
A three-state myo-electric control
Dorcas, D. S., & Scott, R. N. (1966) · Medical & Biological Engineering & Computing · doi:10.1007/bf02476154 · Cited by 106
Auto-and cross-correlation analysis of the electrical activity of muscles
Person, R. S., & Ln, M. (1964) · Medical & Biological Engineering & Computing · doi:10.1007/bf02484214 · Cited by 73
Wave analyses of tissue noise and muscle action potentials
Hayes, K. J. (1960) · Journal of Applied Physiology · doi:10.1152/jappl.1960.15.4.749 · Cited by 56
Scott, R. N. (1967) · Medical & Biological Engineering & Computing · doi:10.1007/bf02474540 · Cited by 40
Muscle substitutes and myo-electric control
Bottomley, A. H., Wilson, A. B. K., & Nightingale, A. (1963) · Radio and Electronic Engineer · doi:10.1049/ree.1963.0169 · Cited by 40
Cited by
Surface EMG based muscle fatigue evaluation in biomechanics
Cifrek, M., Medved, V., Tonković, S., & Ostojić, S. (2009) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2009.01.010 · Cited by 954
EMG profiles during normal human walking: stride-to-stride and inter-subject variability
Winter, D. A., & Yack, H. J. (1987) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(87)90003-4 · Cited by 679
Frequency Parameters of the Myoelectric Signal as a Measure of Muscle Conduction Velocity
Stulen, F. B., & De Luca, C. J. (1981) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1981.324738 · Cited by 576
A Guide for Use and Interpretation of Kinesiologic Electromyographic Data
Soderberg, G. L., & Knutson, L. M. (2000) · Physical Therapy · doi:10.1093/ptj/80.5.485 · Cited by 538
EMG frequency spectrum, muscle structure, and fatigue during dynamic contractions in man
Komi, P. V., & Tesch, P. (1979) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf00421103 · Cited by 461
Metadata
- Authors
- Kwatny, E., Thomas, D. H., & Kwatny, H. G.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1970-10
- Volume
- BME-17
- Issue
- 4
- Pages
- 303-313
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2001538971
- Cited by
- 330
- References
- 8
- FWCI
- 2.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.