Pain Sensations Associated with Electrocutaneous Stimulation
The DOI matches its Crossref record.
Abstract
This paper discusses the results of experiments carried out to determine the feasibility of using electrocutaneous stimulation in sensory substitution systems. The sharp, pricking pain often associated with electrocutaneous stimulation has been found to be a result of thermal damage to the corneal layer of the skin. The high-energy densities required to create this damage often occur, even at moderate stimulation currents, because of the highly nonhomogeneous nature of the skin-electrode interface. However, this pain can be controlled without resorting to electrode pastes by adopting a simple procedure for applying the electrode. The dynamic range and the stability of the sensation magnitude have been measured under paste-free conditions and the conclusion is reached that electrocutaneous stimulation would be a viable alternative to mechanical stimulation in certain sensory substitution applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Electrotactile and vibrotactile displays for sensory substitution systems
Kaczmarek, K. A., Webster, J. G., Bach-y-Rita, P., & Tompkins, W. J. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.68204 · Cited by 827
Minhas, P., Bansal, V., Patel, J., Ho, J. S., Diaz, J., Datta, A., & Bikson, M. (2010) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2010.05.007 · Cited by 267
Capelle, C., Trullemans, C., Arno, P., & Veraart, C. (1998) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.720206 · Cited by 210
Design Guideline for Developing Safe Systems that Apply Electricity to the Human Body
Kono, M., Takahashi, T., Nakamura, H., Miyaki, T., & Rekimoto, J. (2018) · ACM Transactions on Computer-Human Interaction · doi:10.1145/3184743 · Cited by 63
Metadata
- Authors
- Mason, J. L., & MacKay, N. A. M.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1976-09
- Volume
- BME-23
- Issue
- 5
- Pages
- 405-409
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2018984893
- Cited by
- 57
- References
- 0
- FWCI
- 1.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Pain Sensations Associated with Electrocutaneous Stimulation. https://app.cochat.ai/papers/10.1109/tbme.1976.324652
- The paper
- Mason, J. L., & MacKay, N. A. M. (1976). Pain Sensations Associated with Electrocutaneous Stimulation. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.1976.324652
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.