The DOI matches its Crossref record.
Relating Epicardial to Body Surface Potential Distributions by Means of Transfer Coefficients Based on Geometry Measurements
Abstract
Although it has been known throughout this century that a complex sequence of electrical events is produced on the body surface by the electrophysiological properties of the heart, the question of how well these body surface events can be explained mathematically on the basis of experimental measurements of cardiac geometry and electrical activity remains unanswered. Recent advances in experimental capabilities have made possible the near simultaneous measurement of both cardiac epicardial and corresponding body surface potential distributions from in vivo animal preparations using chronically implanted electrodes to keep the volume conductor intact. This report provides a method for finding transfer coefficients that relate the epicardial and body surface potential distributions to each other. The method is based on knowing the geometric location of each electrode, and on having enough electrodes to establish the geometric shape and the potential distribution of closed epicardial and body surfaces. However, the method does not require that either the heart or body surfaces have any special shape, such as that of a sphere, or that any electrical quantities, such as voltage gradients, be known in addition to the potentials. The use of potential distributions to represent heart electrical activity is advantageous since such distributions can be directly measured experimentally, without a transformation to any other form, such as multiple current-generating dipoles, being required. This report includes a statement of the underlying integral equations, the procedure. for finding the equations' coefficients from geometry measurements, some considerations for computer algorithms, and an example.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Potse, M., Dube, B., Richer, J., Vinet, A., & Gulrajani, R. M. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.880875 · Cited by 470
The Solid Angle of a Plane Triangle
Van Oosterom, A., & Strackee, J. (1983) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1983.325207 · Cited by 337
Integration of EEG/MEG with MRI and fMRI
Liu, Z., Ding, L., & He, B. (2006) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2006.1657787 · Cited by 102
Metadata
- Authors
- Barr, R. C., Ramsey, M., & Spach, M. S.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1977-01
- Volume
- BME-24
- Issue
- 1
- Pages
- 1-11
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2010040374
- Cited by
- 312
- References
- 0
- FWCI
- 3.19
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Relating Epicardial to Body Surface Potential Distributions by Means of Transfer Coefficients Based on Geometry Measurements. https://app.cochat.ai/papers/10.1109/tbme.1977.326201
- The paper
- Barr, R. C., Ramsey, M., & Spach, M. S. (1977). Relating Epicardial to Body Surface Potential Distributions by Means of Transfer Coefficients Based on Geometry Measurements. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.1977.326201
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.