The DOI matches its Crossref record.
Magnetic Induction Heating of Ferromagnetic Implants for Inducing Localized Hyperthermia in Deep-Seated Tumors
Abstract
A variable frequency magnetic induction heating system has been developed for localized hyperthermic treatment of deep-seated tumors via power deposition into arrays of 1-2 mm diameter ferromagnetic cylindrical implants. The frequency dependence of implant heating compared to that induced directly into tissues indicates use of frequencies below 4 MHz. Above 10 MHz, tissues are heated directly from the induced eddy currents. Thermographic analyses of temperature distributions induced in tissues equivalent phantom models and in exposed animal tissues in vivo have been performed for several implant materials and array configurations. Results of the thermal dosimetry show that the majority of tissue contained within multiimplant arrays can be heated such that the temperature rises to 55-70 percent of the implant temperature differential. The resulting tissue temperature distribution is dependent on local blood flow and array characteristics, but not significantly on tissue electrical properties. Operating the system at 1.9. MHz, we demonstrate that it is possible to raise an implanted volume to therapeutic temperatures safely, in less than 10 min, with little increase in temperature outside the array boundaries.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Lucia, O., Maussion, P., Dede, E. J., & Burdio, J. M. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2281162 · Cited by 877
Jordan, A., Wust, P., Fählin, H., John, W., Hinz, A., & Felix, R. (1993) · International Journal of Hyperthermia · doi:10.3109/02656739309061478 · Cited by 694
Usable Frequencies in Hyperthermia with Thermal Seeds
Atkinson, W. J., Brezovich, I. A., & Chakraborty, D. P. (1984) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1984.325372 · Cited by 496
Radio-Wave Heating of Iron Oxide Nanoparticles Can Regulate Plasma Glucose in Mice
Stanley, S. A., Gagner, J. E., Damanpour, S., Yoshida, M., Dordick, J. S., & Friedman, J. M. (2012) · Science · doi:10.1126/science.1216753 · Cited by 490
Remotely Triggered Release from Magnetic Nanoparticles
Derfus, A. M., von Maltzahn, G., Harris, T. J., Duza, T., Vecchio, K. S., Ruoslahti, E., & Bhatia, S. N. (2007) · Advanced Materials · doi:10.1002/adma.200700091 · Cited by 282
Metadata
- Authors
- Stauffer, P. R., Cetas, T. C., & Jones, R. C.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1984-02
- Volume
- BME-31
- Issue
- 2
- Pages
- 235-251
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W1987510015
- Cited by
- 201
- References
- 0
- FWCI
- 8.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Magnetic Induction Heating of Ferromagnetic Implants for Inducing Localized Hyperthermia in Deep-Seated Tumors. https://app.cochat.ai/papers/10.1109/tbme.1984.325334
- The paper
- Stauffer, P. R., Cetas, T. C., & Jones, R. C. (1984). Magnetic Induction Heating of Ferromagnetic Implants for Inducing Localized Hyperthermia in Deep-Seated Tumors. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.1984.325334
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.