An Evaluation of Methods for Neuromagnetic Image Reconstruction
The DOI matches its Crossref record.
Abstract
In this paper, we discuss several aspects of a potential new medical imaging modality for producing a quantitative three-dimensional map of neuron current densities associated with brain function. The neuromagnetic image is produced by reconstructing a current dipole field from external magnetic field measurements made with an array of superconducting quantum interference device (SQUID) detectors. This field is produced by numerical inversion of the Biot-Savart equation. The purpose of the work is to investigate fundamental limits on the feasibility of the proposed system under ideal conditions. The following problems are addressed: 1) What are the factors limiting resolution of the system? 2) What is a suitable model for neural activity in the brain? 3) What classes of algorithms are suitable for estimating the model parameters? The major conclusion of this work is that the inversion problem is severely ill-posed and the choice of model and estimation algorithm are crucial in obtaining reasonable solutions. A class of solutions, termed minimum dipole, is proposed as a means of obtaining more acceptable results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Interpreting magnetic fields of the brain: minimum norm estimates
Hämäläinen, M. S., & Ilmoniemi, R. J. (1994) · Medical & Biological Engineering & Computing · doi:10.1007/bf02512476 · Cited by 1,995
Baillet, S., Mosher, J. C., & Leahy, R. M. (2001) · IEEE Signal Processing Magazine · doi:10.1109/79.962275 · Cited by 1,692
Self-citationMultiple dipole modeling and localization from spatio-temporal MEG data
Mosher, J. C., Lewis, P. S., & Leahy, R. M. (1992) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.141192 · Cited by 1,048
Self-citationSekihara, K., Sahani, M., & Nagarajan, S. S. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2004.11.051 · Cited by 477
A critical assessment of connectivity measures for EEG data: A simulation study
Haufe, S., Nikulin, V. V., Müller, K.-R., & Nolte, G. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2012.09.036 · Cited by 334
Metadata
- Authors
- Jeffs, B., Leahy, R., & Singh, M.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1987-09
- Volume
- BME-34
- Issue
- 9
- Pages
- 713-723
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2024688404
- Cited by
- 149
- References
- 0
- FWCI
- 2.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An Evaluation of Methods for Neuromagnetic Image Reconstruction. https://app.cochat.ai/papers/10.1109/tbme.1987.325996
- The paper
- Jeffs, B., Leahy, R., & Singh, M. (1987). An Evaluation of Methods for Neuromagnetic Image Reconstruction. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.1987.325996
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.