A Three-Channel Microcomputer System for Segmentation and Characterization of the Phonocardiogram
The DOI matches its Crossref record.
Abstract
We present here details of a microcomputer system developed to segment the phonocardiogram signal (PCG) and characterize murmurs. Using the ECG and carotid pulse as references, the PCG is segmented into systolic and diastolic parts. Four parameters representing the time and frequency domain characteristics of the signal segments are then computed. Results of application of the methods to 47 phonocardiogram signals are presented. The use of these parameters for the detection and classification of murmurs is discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 12
- 10.1007/BF02476124 · doi:10.1007/bf02476124
- 10.1007/BF02442475 · doi:10.1007/bf02442475
- 10.1109/TBME.1984.325302 · doi:10.1109/tbme.1984.325302
- 10.1016/S0002-8703(41)90904-3 · doi:10.1016/s0002-8703(41)90904-3
- lehner, 1984, use of the carotid pulse in identification of the second heart sound, Proc Int Conf Comput Syst Signal Processing Indian Inst Sci and IEEE, 1414
- 10.1001/jama.1960.03030010034009 · DOI · Paper page
- 10.1016/0141-5425(79)90159-6 · doi:10.1016/0141-5425(79)90159-6
- tavel, 1978, Clinical Phonocardiography and External Pulse Recording
- 10.1109/TBME.1979.326420 · doi:10.1109/tbme.1979.326420
- 10.1016/0002-9149(71)90360-2 · DOI
- rushmer, 1976, Cardiovascular Dynamics
- 10.1016/0010-4809(73)90064-5 · doi:10.1016/0010-4809(73)90064-5
Cited by
Heart sound segmentation algorithm based on heart sound envelogram
Liang, H., Lukkarinen, S., & Hartimo, I. (2002) · Computers in Cardiology 1997 · doi:10.1109/cic.1997.647841 · Cited by 414
Neural network classification of homomorphic segmented heart sounds
Gupta, C. N., Palaniappan, R., Swaminathan, S., & Krishnan, S. M. (2007) · Applied Soft Computing · doi:10.1016/j.asoc.2005.06.006 · Cited by 251
“Many of them depend on ECG signal or/and carotid pulse, as [5].”
BackgroundAlgorithms for Automatic Analysis and Classification of Heart Sounds–A Systematic Review
Dwivedi, A. K., Imtiaz, S. A., & Rodriguez-Villegas, E. (2019) · IEEE Access · doi:10.1109/access.2018.2889437 · Cited by 195
“pulse reference based methods [72], [90]–[99], probabilistic models [45], [52], [65], [67], [77], [80], [100]–[105], feature based methods [25], [29], [49], [61], [75], [106]–[108],”
BackgroundA heart sound segmentation algorithm using wavelet decomposition and reconstruction
Huiying, L., Sakari, L., & Iiro, H. (2002) · Proceedings of the 19th Annual International Conference of the IEEE Engineering in Medicine and Biology Society. 'Magnificent Milestones and Emerging Opportunities in Medical Engineering' (Cat. No.97CH36136) · doi:10.1109/iembs.1997.757028 · Cited by 189
Khalifa, Y., Coyle, J. L., & Sejdić, E. (2020) · Scientific Reports · doi:10.1038/s41598-020-65492-1 · Cited by 82
Sejdic, E., Steele, C. M., & Chau, T. (2009) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.2010504 · Cited by 73
“In particular, several successful methods rely on multiple channels of information to enhance segmentation [14], [15].”
MethodSwallow segmentation with artificial neural networks and multi-sensor fusion
Lee, J., Steele, C. M., & Chau, T. (2009) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2009.07.001 · Cited by 40
Metadata
- Authors
- Lehner, R. J., & Rangayyan, R. M.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 1987-06
- Volume
- BME-34
- Issue
- 6
- Pages
- 485-489
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2041088948
- Cited by
- 110
- References
- 0
- FWCI
- 2.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.