The DOI matches its Crossref record.
Epileptic seizure prediction using hybrid feature selection over multiple intracranial EEG electrode contacts: a report of four patients
Abstract
Epileptic seizure prediction has steadily evolved from its conception in the 1970s, to proof-of-principle experiments in the late 1980s and 1990s, to its current place as an area of vigorous, clinical and laboratory investigation. As a step toward practical implementation of this technology in humans, we present an individualized method for selecting electroencephalogram (EEG) features and electrode locations for seizure prediction focused on precursors that occur within ten minutes of electrographic seizure onset. This method applies an intelligent genetic search process to EEG signals simultaneously collected from multiple intracranial electrode contacts and multiple quantitative features derived from these signals. The algorithm is trained on a series of baseline and preseizure records and then validated on other, previously unseen data using split sample validation techniques. The performance of this method is demonstrated on multiday recordings obtained from four patients implanted with intracranial electrodes during evaluation for epilepsy surgery. An average probability of prediction (or block sensitivity) of 62.5% was achieved in this group, with an average block false positive (FP) rate of 0.2775 FP predictions/h, corresponding to 90.47% specificity. These findings are presented as an example of a method for training, testing and validating a seizure prediction system on data from individual patients. Given the heterogeneity of epilepsy, it is likely that methods of this type will be required to configure intelligent devices for treating epilepsy to each individual's neurophysiology prior to clinical deployment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Seizure prediction: the long and winding road
Mormann, F., Andrzejak, R. G., Elger, C. E., & Lehnertz, K. (2007) · Brain · doi:10.1093/brain/awl241 · Cited by 1,109
(2004) · Dictionary of Strategy: Strategic Management A-Z · doi:10.4135/9781452229805.n17 · Cited by 938
Classification of patterns of EEG synchronization for seizure prediction
Mirowski, P., Madhavan, D., LeCun, Y., & Kuzniecky, R. (2009) · Clinical Neurophysiology · doi:10.1016/j.clinph.2009.09.002 · Cited by 380
Epileptic seizure detection using hybrid machine learning methods
Subasi, A., Kevric, J., & Abdullah Canbaz, M. (2019) · Neural Computing and Applications · doi:10.1007/s00521-017-3003-y · Cited by 309
Li, Y., Liu, Y., Cui, W.-G., Guo, Y.-Z., Huang, H., & Hu, Z.-Y. (2020) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2020.2973434 · Cited by 285
Real-Time Epileptic Seizure Prediction Using AR Models and Support Vector Machines
Chisci, L., Mavino, A., Perferi, G., Sciandrone, M., Anile, C., Colicchio, G., & Fuggetta, F. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2038990 · Cited by 255
Metadata
- Authors
- D'Alessandro, M., Esteller, R., Vachtsevanos, G., Hinson, A., Echauz, J., & Litt, B.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2003-05
- Volume
- 50
- Issue
- 5
- Pages
- 603-615
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2158585918
- Cited by
- 271
- References
- 0
- FWCI
- 4.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.