The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Atrial Activity Extraction for Atrial Fibrillation Analysis Using Blind Source Separation
Abstract
This contribution addresses the extraction of atrial activity (AA) from real electrocardiogram (ECG) recordings of atrial fibrillation (AF). We show the appropriateness of independent component analysis (ICA) to tackle this biomedical challenge when regarded as a blind source separation (BSS) problem. ICA is a statistical tool able to reconstruct the unobservable independent sources of bioelectric activity which generate, through instantaneous linear mixing, a measurable set of signals. The three key hypothesis that make ICA applicable in the present scenario are discussed and validated: 1) AA and ventricular activity (VA) are generated by sources of independent bioelectric activity; 2) AA and VA present non-Gaussian distributions; and 3) the generation of the surface ECG potentials from the cardioelectric sources can be regarded as a narrow-band linear propagation process. To empirically endorse these claims, an ICA algorithm is applied to recordings from seven patients with persistent AF. We demonstrate that the AA source can be identified using a kurtosis-based reordering of the separated signals followed by spectral analysis of the sub-Gaussian sources. In contrast to traditional methods, the proposed BSS-based approach is able to obtain a unified AA signal by exploiting the atrial information present in every ECG lead, which results in an increased robustness with respect to electrode selection and placement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
BioelectromagnetismPrinciples and Applications of Bioelectric and Biomagnetic Fields
Malmivuo, J., & Plonsey, R. (1995) · doi:10.1093/acprof:oso/9780195058239.001.0001 · Cited by 1,834
Cited by
Heartbeat Classification Using Morphological and Dynamic Features of ECG Signals
Ye, C., Kumar, B. V. K. V., & Coimbra, M. T. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2213253 · Cited by 522
Filgueiras-Rama, D., Price, N. F., Martins, R. P., Yamazaki, M., Avula, U. M. R., Kaur, K., Kalifa, J., Ennis, S. R., Hwang, E., Devabhaktuni, V., et al. (2012) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.111.969519 · Cited by 70
Metadata
- Authors
- Rieta, J. J., Castells, F., Sanchez, C., Zarzoso, V., & Millet, J.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2004-07
- Volume
- 51
- Issue
- 7
- Pages
- 1176-1186
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2124033264
- Cited by
- 263
- References
- 1
- FWCI
- 9.29
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Atrial Activity Extraction for Atrial Fibrillation Analysis Using Blind Source Separation. https://app.cochat.ai/papers/10.1109/tbme.2004.827272
- The paper
- Rieta, J. J., Castells, F., Sanchez, C., Zarzoso, V., & Millet, J. (2004). Atrial Activity Extraction for Atrial Fibrillation Analysis Using Blind Source Separation. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2004.827272
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.