The DOI matches its Crossref record.
Encoding Frequency Modulation to Improve Cochlear Implant Performance in Noise
Open accessAbstract
Different from traditional Fourier analysis, a signal can be decomposed into amplitude and frequency modulation components. The speech processing strategy in most modern cochlear implants only extracts and encodes amplitude modulation in a limited number of frequency bands. While amplitude modulation encoding has allowed cochlear implant users to achieve good speech recognition in quiet, their performance in noise is severely compromised. Here, we propose a novel speech processing strategy that encodes both amplitude and frequency modulations in order to improve cochlear implant performance in noise. By removing the center frequency from the subband signals and additionally limiting the frequency modulation's range and rate, the present strategy transforms the fast-varying temporal fine structure into a slowly varying frequency modulation signal. As a first step, we evaluated the potential contribution of additional frequency modulation to speech recognition in noise via acoustic simulations of the cochlear implant. We found that while amplitude modulation from a limited number of spectral bands is sufficient to support speech recognition in quiet, frequency modulation is needed to support speech recognition in noise. In particular, improvement by as much as 71 percentage points was observed for sentence recognition in the presence of a competing voice. The present result strongly suggests that frequency modulation be extracted and encoded to improve cochlear implant performance in realistic listening situations. We have proposed several implementation methods to stimulate further investigation. Index Terms-Amplitude modulation, cochlear implant, fine structure, frequency modulation, signal processing, speech recognition, temporal envelope.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cochlear Implants: System Design, Integration, and Evaluation
Zeng, F.-G., Rebscher, S., Harrison, W., Sun, X., & Feng, H. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008250 · Cited by 878
Self-citationCochlear implants: A remarkable past and a brilliant future
Wilson, B. S., & Dorman, M. F. (2008) · Hearing Research · doi:10.1016/j.heares.2008.06.005 · Cited by 868
Moore, B. C. J. (2008) · Journal of the Association for Research in Otolaryngology · doi:10.1007/s10162-008-0143-x · Cited by 421
Zeng, F.-G. (2004) · Trends in Amplification · doi:10.1177/108471380400800102 · Cited by 401
Self-citationCochlear implants: Current designs and future possibilities
Wilson, B. S. (2008) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2007.10.0173 · Cited by 396
Speech recognition with amplitude and frequency modulations
Zeng, F.-G., Nie, K., Stickney, G. S., Kong, Y.-Y., Vongphoe, M., Bhargave, A., Wei, C., & Cao, K. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406460102 · Cited by 383
Self-citation
Metadata
- Authors
- Nie, K., Stickney, G., & Zeng, F.-G.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2005-01
- Volume
- 52
- Issue
- 1
- Pages
- 64-73
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2106257221
- Cited by
- 209
- References
- 0
- FWCI
- 5.44
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.