The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Quantifying Errors in Spectral Estimates of HRV Due to Beat Replacement and Resampling
Abstract
Spectral estimates of heart rate variability (HRV) often involve the use of techniques such as the fast Fourier transform (FFT), which require an evenly sampled time series. HRV is calculated from the variations in the beat-to-beat (RR) interval timing of the cardiac cycle which are inherently irregularly spaced in time. In order to produce an evenly sampled time series prior to FFT-based spectral estimation, linear or cubic spline resampling is usually employed. In this paper, by using a realistic artificial RR interval generator, interpolation and resampling is shown to result in consistent over-estimations of the power spectral density (PSD) compared with the theoretical solution. The Lomb-Scargle (LS) periodogram, a more appropriate spectral estimation technique for unevenly sampled time series that uses only the original data, is shown to provide a superior PSD estimate. Ectopy removal or replacement is shown to be essential regardless of the spectral estimation technique. Resampling and phantom beat replacement is shown to decrease the accuracy of PSD estimation, even at low levels of ectopy or artefact. A linear relationship between the frequency of ectopy/artefact and the error (mean and variance) of the PSD estimate is demonstrated. Comparisons of PSD estimation techniques performed on real RR interval data during minimally active segments (sleep) demonstrate that the LS periodogram provides a less noisy spectral estimate of HRV.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heart Rate Variability: Standards of Measurement, Physiological Interpretation, and Clinical Use
Electrophysiology, T. F. O. T. E. S. O. C. T. N. A. (1996) · Circulation · doi:10.1161/01.cir.93.5.1043 · Cited by 17,159
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
Welch, P. (1967) · IEEE Transactions on Audio and Electroacoustics · doi:10.1109/tau.1967.1161901 · Cited by 12,277
de Boor, C. (1978) · Applied Mathematical Sciences · doi:10.1007/978-1-4612-6333-3 · Cited by 11,944
Scargle, J. D. (1982) · The Astrophysical Journal · doi:10.1086/160554 · Cited by 7,376
On the use of windows for harmonic analysis with the discrete Fourier transform
Harris, F. J. (1978) · Proceedings of the IEEE · doi:10.1109/proc.1978.10837 · Cited by 7,326
Least-squares frequency analysis of unequally spaced data
Lomb, N. R. (1976) · Astrophysics and Space Science · doi:10.1007/bf00648343 · Cited by 5,717
A dynamical model for generating synthetic electrocardiogram signals
McSharry, P. E., Clifford, G. D., Tarassenko, L., & Smith, L. A. (2003) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2003.808805 · Cited by 1,224
Self-citationAnalysis of Heart Rate Variability
SAYKRS, B. M. (1973) · Ergonomics · doi:10.1080/00140137308924479 · Cited by 946
An Efficient Algorithm for Spectral Analysis of Heart Rate Variability
Berger, R. D., Akselrod, S., Gordon, D., & Cohen, R. J. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325789 · Cited by 807
Cited by
Quintana, D. S., Alvares, G. A., & Heathers, J. A. J. (2016) · Translational Psychiatry · doi:10.1038/tp.2016.73 · Cited by 420
Weippert, M., Kumar, M., Kreuzfeld, S., Arndt, D., Rieger, A., & Stoll, R. (2010) · European Journal of Applied Physiology · doi:10.1007/s00421-010-1415-9 · Cited by 300
ARTiiFACT: a tool for heart rate artifact processing and heart rate variability analysis.
Kaufmann, T., Sütterlin, S., Schulz, S. M., & Vögele, C. (2011) · Behavior Research Methods · doi:10.3758/s13428-011-0107-7 · Cited by 284
On the validity of using the Polar RS800 heart rate monitor for heart rate variability research
Quintana, D. S., Heathers, J. A. J., & Kemp, A. H. (2012) · European Journal of Applied Physiology · doi:10.1007/s00421-012-2453-2 · Cited by 118
Ellis, R. J., Zhu, B., Koenig, J., Thayer, J. F., & Wang, Y. (2015) · Physiological Measurement · doi:10.1088/0967-3334/36/9/1827 · Cited by 85
Metadata
- Authors
- Clifford, G. D., & Tarassenko, L.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2005-04
- Volume
- 52
- Issue
- 4
- Pages
- 630-638
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2120599197
- Cited by
- 285
- References
- 29
- FWCI
- 3.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.