CoChat

Estimation of the Cortical Connectivity by High-Resolution EEG and Structural Equation Modeling: Simulations and Application to Finger Tapping Data

Astolfi, L., Cincotti, F., Babiloni, C., Carducci, F., Basilisco, A., Rossini, P.M., Salinari, S., Mattia, D., Cerutti, S., BenDayan, D., Ding, L., Ni, Y., He, B., Babiloni, F. · 2005 · IEEE Transactions on Biomedical Engineering
Cited by 76

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

Today, the concept of brain connectivity plays a central role in the neuroscience. While functional connectivity is defined as the temporal coherence between the activities of different brain areas, the effective connectivity is defined as the simplest brain circuit that would produce the same temporal relationship as observed experimentally between cortical sites. The most used method to estimate effective connectivity in neuroscience is the structural equation modeling (SEM), typically used on data related to the brain hemodynamic behavior. However, the use of hemodynamic measures limits the temporal resolution on which the brain process can be followed. The present research proposes the use of the SEM approach on the cortical waveforms estimated from the high-resolution EEG data, which exhibits a good spatial resolution and a higher temporal resolution than hemodynamic measures. We performed a simulation study, in which different main factors were systematically manipulated in the generation of test signals, and the errors in the estimated connectivity were evaluated by the analysis of variance (ANOVA). Such factors were the signal-to-noise ratio and the duration of the simulated cortical activity. Since SEM technique is based on the use of a model formulated on the basis of anatomical and physiological constraints, different experimental conditions were analyzed, in order to evaluate the effect of errors made in the a priori model formulation on its performances. The feasibility of the proposed approach has been shown in a human study using high-resolution EEG recordings related to finger tapping movements.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.2005.845371

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 76

Metadata

Authors
Astolfi, L., Cincotti, F., Babiloni, C., Carducci, F., Basilisco, A., Rossini, P. M., Salinari, S., Mattia, D., Cerutti, S., BenDayan, D., Ding, L., Ni, Y., He, B., & Babiloni, F.
Venue
IEEE Transactions on Biomedical Engineering
Published
2005-05
Volume
52
Issue
5
Pages
757-768
ISSN
0018-9294 (ISSN-L)
OpenAlex
W2161624575
Cited by
76
References
5
FWCI
4.05
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.