The DOI matches its Crossref record.
A Robust Method for ECG-Based Estimation of the Respiratory Frequency During Stress Testing
Abstract
A robust method is presented for electrocardiogram (ECG)-based estimation of the respiratory frequency during stress testing. Such ECGs contain highly nonstationary noise and exhibit changes in QRS morphology which, when combined with the dynamic nature of the respiratory frequency, make most existing methods break down. The present method exploits the oscillatory pattern of the rotation angles of the heart's electrical axis as induced by respiration. The series of rotation angles, obtained from least-squares loop alignment, is subject to power spectral analysis and estimation of the respiratory frequency. Robust techniques are introduced to handle the nonstationary properties of exercise ECGs. The method is evaluated by means of both simulated signals, and ECG/airflow signals recorded from 14 volunteers and 20 patients during stress testing. The resulting respiratory frequency estimation error is, for simulated signals, equal to 0.5% +/- 0.2%, mean +/- SD (0.002 +/- 0.001 Hz), whereas the error between respiratory frequencies of the ECG-derived method and the airflow signals is 5.9% +/- 4% (0.022 +/- 0.016Hz). The results suggest that the method is highly suitable for analysis of noisy ECG signals recorded during stress testing.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Analysis of Heart Rate Variability and Implication of Different Factors on Heart Rate Variability
Tiwari, R., Kumar, R., Malik, S., Raj, T., & Kumar, P. (2021) · Current Cardiology Reviews · doi:10.2174/1573403x16999201231203854 · Cited by 463
Quintana, D. S., Alvares, G. A., & Heathers, J. A. J. (2016) · Translational Psychiatry · doi:10.1038/tp.2016.73 · Cited by 420
Breathing Rate Estimation From the Electrocardiogram and Photoplethysmogram: A Review
Charlton, P. H., Birrenkott, D. A., Bonnici, T., Pimentel, M. A. F., Johnson, A. E. W., Alastruey, J., Tarassenko, L., Watkinson, P. J., Beale, R., & Clifton, D. A. (2018) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2017.2763681 · Cited by 379
Automatic ECG-Based Emotion Recognition in Music Listening
Hsu, Y.-L., Wang, J.-S., Chiang, W.-C., & Hung, C.-H. (2020) · IEEE Transactions on Affective Computing · doi:10.1109/taffc.2017.2781732 · Cited by 258
Heart rate variability and occupational stress—systematic review
JÄRVELIN-PASANEN, S., SINIKALLIO, S., & TARVAINEN, M. P. (2018) · Industrial Health · doi:10.2486/indhealth.2017-0190 · Cited by 253
Metadata
- Authors
- Bailon, R., Sornmo, L., & Laguna, P.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2006-07
- Volume
- 53
- Issue
- 7
- Pages
- 1273-1285
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2141040858
- Cited by
- 190
- References
- 0
- FWCI
- 3.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Robust Method for ECG-Based Estimation of the Respiratory Frequency During Stress Testing. https://app.cochat.ai/papers/10.1109/tbme.2006.871888
- The paper
- Bailon, R., Sornmo, L., & Laguna, P. (2006). A Robust Method for ECG-Based Estimation of the Respiratory Frequency During Stress Testing. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2006.871888
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.