Body Movement Activity Recognition for Ambulatory Cardiac Monitoring
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Wearable electrocardiogram (W-ECG) recorders are increasingly in use by people suffering from cardiac abnormalities who also choose to lead an active lifestyle. The challenge presently is that the ECG signal is influenced by motion artifacts induced by body movement activity (BMA) of the wearer. The usual practice is to develop effective filtering algorithms which will eliminate artifacts. Instead, our goal is to detect the motion artifacts and classify the type of BMA from the ECG signal itself. We have recorded the ECG signals during specified BMAs, e.g., sitting still, walking, movements of arms and climbing stairs, etc. with a single-lead system. The collected ECG signal during BMA is presumed to be an additive mix of signals due to cardiac activities, motion artifacts and sensor noise. A particular class of BMA is characterized by applying eigen decomposition on the corresponding ECG data. The classification accuracies range from 70% to 98% for various class combinations of BMAs depending on their uniqueness based on this technique. The above classification is also useful for analysis of P and T waves in the presence of BMA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855 · cited 1×
“The R-peaks in the ECG signals are detected using the Pan-Tompkins method [10].”
Method
Cited by
A Survey on Wearable Sensor-Based Systems for Health Monitoring and Prognosis
Pantelopoulos, A., & Bourbakis, N. G. (2010) · IEEE Transactions on Systems Man and Cybernetics Part C (Applications and Reviews) · doi:10.1109/tsmcc.2009.2032660 · Cited by 2,296
“Another interesting effort is described in [57], where the au-”
BackgroundWearable Sensors for Biochemical Sweat Analysis
Bandodkar, A. J., Jeang, W. J., Ghaffari, R., & Rogers, J. A. (2019) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-061318-114910 · Cited by 387
McManus, D. D., Lee, J., Maitas, O., Esa, N., Pidikiti, R., Carlucci, A., Harrington, J., Mick, E., & Chon, K. H. (2013) · Heart Rhythm · doi:10.1016/j.hrthm.2012.12.001 · Cited by 253
Application of data fusion techniques and technologies for wearable health monitoring
King, R. C., Villeneuve, E., White, R. J., Sherratt, R. S., Holderbaum, W., & Harwin, W. S. (2017) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2016.12.011 · Cited by 182
“Exceptions include Pawar et al. [60] , who performed body movement classification using artifacts present in wearable ECG signals, and Roy et al. [46] who combined surface EMG with accelerometers for activity recognition.”
Guo, H., Chen, L., Peng, L., & Chen, G. (2016) · Proceedings of the 2016 ACM International Joint Conference on Pervasive and Ubiquitous Computing · doi:10.1145/2971648.2971708 · Cited by 83
“Traditionally, researchers attempt to recognize human activity only from accelerometer data [1, 2, 3] or other data (e.g., electrocardiogram [4]).”
Background
Metadata
- Authors
- Pawar, T., Chaudhuri, S., & Duttagupta, S. P.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2007-05
- Volume
- 54
- Issue
- 5
- Pages
- 874-882
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2110245703
- Cited by
- 91
- References
- 1
- FWCI
- 4.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.