The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Use of Sample Entropy Approach to Study Heart Rate Variability in Obstructive Sleep Apnea Syndrome
Abstract
Sample entropy, a nonlinear signal processing approach, was used as a measure of signal complexity to evaluate the cyclic behavior of heart rate variability (HRV) in obstructive sleep apnea syndrome (OSAS). In a group of 10 normal and 25 OSA subjects, the sample entropy measure showed that normal subjects have significantly more complex HRV pattern than the OSA subjects (p < 0.005). When compared with spectral analysis in a minute-by-minute classification, sample entropy had an accuracy of 70.3% (69.5% sensitivity, 70.8% specificity) while the spectral analysis had an accuracy of 70.4% (71.3% sensitivity, 69.9% specificity). The combination of the two methods improved the accuracy to 72.9% (72.2% sensitivity, 73.3% specificity). The sample entropy approach does not show major improvement over the existing methods. In fact, its accuracy in detecting sleep apnea is relatively low in the well classified data of the physionet. Its main achievement however, is the simplicity of computation. Sample entropy and other nonlinear methods might be useful tools to detect apnea episodes during sleep.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855
Approximate entropy as a measure of system complexity.
Pincus, S. M. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.6.2297 · Cited by 5,811
Cited by
Heart Rate Variability in Psychology: A Review of HRV Indices and an Analysis Tutorial
Pham, T., Lau, Z. J., Chen, S. H. A., & Makowski, D. (2021) · Sensors · doi:10.3390/s21123998 · Cited by 480
Differential entropy feature for EEG-based vigilance estimation
Shi, L.-C., Jiao, Y.-Y., & Lu, B.-L. (2013) · 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2013.6611075 · Cited by 396
On the use of sample entropy to analyze human postural sway data
Ramdani, S., Seigle, B., Lagarde, J., Bouchara, F., & Bernard, P. L. (2009) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2009.06.004 · Cited by 298
Li, K., Pan, W., Li, Y., Jiang, Q., & Liu, G. (2018) · Neurocomputing · doi:10.1016/j.neucom.2018.03.011 · Cited by 254
Song, Y., Crowcroft, J., & Zhang, J. (2012) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2012.07.003 · Cited by 252
Song, Y., & Liò, P. (2010) · Journal of Biomedical Science and Engineering · doi:10.4236/jbise.2010.36078 · Cited by 191
Photoplethysmogram Signal Quality Evaluation by Unsupervised Learning Approach
Roy, M. S., Gupta, R., & Sharma, K. D. (2020) · 2020 IEEE Applied Signal Processing Conference (ASPCON) · doi:10.1109/aspcon49795.2020.9276733 · Cited by 24
Metadata
- Authors
- Al-Angari, H. M., & Sahakian, A. V.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2007-10
- Volume
- 54
- Issue
- 10
- Pages
- 1900-1904
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2147783122
- Cited by
- 244
- References
- 3
- FWCI
- 6.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.