The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Microbubble-Size Dependence of Focused Ultrasound-Induced Blood–Brain Barrier Opening in Mice In Vivo
Open accessAbstract
The therapeutic efficacy of neurological agents is severely limited, because large compounds do not cross the blood-brain barrier (BBB). Focused ultrasound (FUS) sonication in the presence of microbubbles has been shown to temporarily open the BBB, allowing systemically administered agents into the brain. Until now, polydispersed microbubbles (1-10 microm in diameter) were used, and, therefore, the bubble sizes better suited for inducing the opening remain unknown. Here, the FUS-induced BBB opening dependence on microbubble size is investigated. Bubbles at 1-2 and 4-5 microm in diameter were separately size-isolated using differential centrifugation before being systemically administered in mice (n = 28). The BBB opening pressure threshold was identified by varying the peak-rarefactional pressure amplitude. BBB opening was determined by fluorescence enhancement due to systemically administered, fluorescent-tagged, 3-kDa dextran. The identified threshold fell between 0.30 and 0.46 MPa in the case of 1-2 microm bubbles and between 0.15 and 0.30 MPa in the 4-5 microm case. At every pressure studied, the fluorescence was greater with the 4-5 mum than with the 1-2 microm bubbles. At 0.61 MPa, in the 1-2 microm bubble case, the fluorescence amount and area were greater in the thalamus than in the hippocampus. In conclusion, it was determined that the FUS-induced BBB opening was dependent on both the size distribution in the injected microbubble volume and the brain region targeted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Astrocyte-endothelial interactions at the blood-brain barrier
Abbott, N. J., Rönnbäck, L., & Hansson, E. (2006) · Nature Reviews Neuroscience · doi:10.1038/nrn1824 · Cited by 5,595
The Blood-Brain Barrier in Health and Chronic Neurodegenerative Disorders
Zlokovic, B. V. (2008) · Neuron · doi:10.1016/j.neuron.2008.01.003 · Cited by 3,280
Choi, J. J., Pernot, M., Brown, T. R., Small, S. A., & Konofagou, E. E. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/18/004 · Cited by 141
Self-citation
Cited by
Aryal, M., Arvanitis, C. D., Alexander, P. M., & McDannold, N. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2014.01.008 · Cited by 443
Stereotactic modulation of blood-brain barrier permeability to enhance drug delivery
Appelboom, G., Detappe, A., LoPresti, M., Kunjachan, S., Mitrasinovic, S., Goldman, S., Chang, S. D., & Tillement, O. (2016) · Neuro-Oncology · doi:10.1093/neuonc/now137 · Cited by 340
Focused ultrasound-mediated drug delivery through the blood–brain barrier
Burgess, A., Shah, K., Hough, O., & Hynynen, K. (2015) · Expert Review of Neurotherapeutics · doi:10.1586/14737175.2015.1028369 · Cited by 323
Krishna, V., Sammartino, F., & Rezai, A. (2018) · JAMA Neurology · doi:10.1001/jamaneurol.2017.3129 · Cited by 289
Liu, H.-L., Fan, C.-H., Ting, C.-Y., & Yeh, C.-K. (2014) · Theranostics · doi:10.7150/thno.8074 · Cited by 276
Metadata
- Authors
- Choi, J. J., Feshitan, J. A., Baseri, B., Wang, S., Tung, Y.-S., Borden, M. A., & Konofagou, E. E.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2010-01
- Volume
- 57
- Issue
- 1
- Pages
- 145-154
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2156360500
- Cited by
- 261
- References
- 3
- FWCI
- 6.79
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Microbubble-Size Dependence of Focused Ultrasound-Induced Blood–Brain Barrier Opening in Mice In Vivo. https://app.cochat.ai/papers/10.1109/tbme.2009.2034533
- The paper
- Choi, J. J., Feshitan, J. A., Baseri, B., Wang, S., Tung, Y.-S., Borden, M. A., & Konofagou, E. E. (2010). Microbubble-Size Dependence of Focused Ultrasound-Induced Blood–Brain Barrier Opening in Mice In Vivo. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2009.2034533
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.