Orthogonal Fuzzy Neighborhood Discriminant Analysis for Multifunction Myoelectric Hand Control
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Developing accurate and powerful electromyogram (EMG) driven prostheses controllers that can provide the amputees with effective control on their artificial limbs, has been the focus of a great deal of research in the past few years. One of the major challenges in such research is extracting an informative subset of features that can best discriminate between the different forearm movements. In this paper, a new dimensionality reduction method, referred to as orthogonal fuzzy neighborhood discriminant analysis (OFNDA), is proposed as a response to such a challenge. Unlike existing attempts in fuzzy linear discriminant analysis, the objective of the proposed OFNDA is to minimize the distance between samples that belong to the same class and maximize the distance between the centers of different classes, while taking into account the contribution of the samples to the different classes. The proposed OFNDA is validated on EMG datasets collected from seven subjects performing a range of 5 to 10 classes of forearm movements. Practical results indicate the significance of OFNDA in comparison to many other feature projection methods (including locality preserving and uncorrelated variants of discriminant analysis) with accuracies ranging from 97.66% to 87.84% for 5 to 10 classes of movements, respectively, using only two EMG electrodes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new strategy for multifunction myoelectric control
Hudgins, B., Parker, P., & Scott, R. N. (1993) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.204774 · Cited by 2,149 · cited 1×
“Advances in EMG studies revealed that there are distinct differences in the temporal structure associated with different kinds of the arm movements [ 1 ].”
BackgroundMyoelectric control systems—A survey
Asghari Oskoei, M., & Hu, H. (2007) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2007.07.009 · Cited by 1,244
Cited by
Feature reduction and selection for EMG signal classification
Phinyomark, A., Phukpattaranont, P., & Limsakul, C. (2012) · Expert Systems with Applications · doi:10.1016/j.eswa.2012.01.102 · Cited by 1,542
Alzubaidi, L., Bai, J., Al-Sabaawi, A., Santamaría, J., Albahri, A. S., Al-dabbagh, B. S. N., Fadhel, M. A., Manoufali, M., Zhang, J., Al-Timemy, A. H., et al. (2023) · Journal of Big Data · doi:10.1186/s40537-023-00727-2 · Cited by 907
EMG feature evaluation for improving myoelectric pattern recognition robustness
Phinyomark, A., Quaine, F., Charbonnier, S., Serviere, C., Tarpin-Bernard, F., & Laurillau, Y. (2013) · Expert Systems with Applications · doi:10.1016/j.eswa.2013.02.023 · Cited by 643
A Review of Classification Techniques of EMG Signals during Isotonic and Isometric Contractions
Nazmi, N., Abdul Rahman, M., Yamamoto, S.-I., Ahmad, S., Zamzuri, H., & Mazlan, S. (2016) · Sensors · doi:10.3390/s16081304 · Cited by 377
Myoelectric control of prosthetic hands: state-of-the-art review
Geethanjali, P. (2016) · Medical Devices: Evidence and Research · doi:10.2147/mder.s91102 · Cited by 342
Metadata
- Authors
- Khushaba, R. N., Al-Ani, A., & Al-Jumaily, A.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2010-06
- Volume
- 57
- Issue
- 6
- Pages
- 1410-1419
- ISSN
- 0018-9294 (ISSN-L)
- OpenAlex
- W2106195076
- Cited by
- 110
- References
- 2
- FWCI
- 4.91
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.