Automatic and Unsupervised Snore Sound Extraction From Respiratory Sound Signals
Open accessThe DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
In this paper, an automatic and unsupervised snore detection algorithm is proposed. The respiratory sound signals of 30 patients with different levels of airway obstruction were recorded by two microphones: one placed over the trachea (the tracheal microphone), and the other was a freestanding microphone (the ambient microphone). All the recordings were done simultaneously with full-night polysomnography during sleep. The sound activity episodes were identified using the vertical box (V-Box) algorithm. The 500-Hz subband energy distribution and principal component analysis were used to extract discriminative features from sound episodes. An unsupervised fuzzy C-means clustering algorithm was then deployed to label the sound episodes as either snore or no-snore class, which could be breath sound, swallowing sound, or any other noise. The algorithm was evaluated using manual annotation of the sound signals. The overall accuracy of the proposed algorithm was found to be 98.6% for tracheal sounds recordings, and 93.1% for the sounds recorded by the ambient microphone.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A NEW MEASURE OF RANK CORRELATION
KENDALL, M. G. (1938) · Biometrika · doi:10.1093/biomet/30.1-2.81 · Cited by 7,269
Kushida, C. A., Littner, M. R., Morgenthaler, T., Alessi, C. A., Bailey, D., Coleman, J., Friedman, L., Hirshkowitz, M., Kapen, S., Kramer, M., et al. (2005) · Sleep · doi:10.1093/sleep/28.4.499 · Cited by 2,054
(2002) · Springer Series in Statistics · doi:10.1007/b98835 · Cited by 919
Schwab, R. J., Gupta, K. B., Gefter, W. B., Metzger, L. J., Hoffman, E. A., & Pack, A. I. (1995) · American journal of respiratory and critical care medicine · doi:10.1164/ajrccm.152.5.7582313 · Cited by 819
Predictors and prevalence of obstructive sleep apnoea and snoring in 1001 middle aged men.
Stradling, J. R., & Crosby, J. H. (1991) · Thorax · doi:10.1136/thx.46.2.85 · Cited by 640
BURMAN, P. (1989) · Biometrika · doi:10.1093/biomet/76.3.503 · Cited by 634
Upper Airway Collapsibility in Snorers and in Patients with Obstructive Hypopnea and Apnea
Gleadhill, I. C., Schwartz, A. R., Schubert, N., Wise, R. A., Permutt, S., & Smith, P. L. (1991) · American Review of Respiratory Disease · doi:10.1164/ajrccm/143.6.1300 · Cited by 453
Size and Mechanical Properties of the Pharynx in Healthy Men and Women
Brooks, L. J., & Strohl, K. P. (1992) · American Review of Respiratory Disease · doi:10.1164/ajrccm/146.6.1394 · Cited by 180
Cited by
Song, C., Liu, K., Zhang, X., Chen, L., & Xian, X. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2498199 · Cited by 252
“These signals including ECG [4], [5], SaO2 [6], [7], snoring signal [8], [9], midsagittal jaw movement [10], respiratory sound [11], thoracic effort [12], and EEG signals [13] or a combination of these [14], have been found in the literature.”
BackgroundBreathPrint: Breathing Acoustics-based User Authentication
Chauhan, J., Hu, Y., Seneviratne, S., Misra, A., Seneviratne, A., & Lee, Y. (2017) · Proceedings of the 15th Annual International Conference on Mobile Systems, Applications, and Services · doi:10.1145/3081333.3081355 · Cited by 170
Chen, L., Zhang, X., & Song, C. (2015) · IEEE Transactions on Automation Science and Engineering · doi:10.1109/tase.2014.2345667 · Cited by 159
“Among these studies, methods based on signals such as ECG [5]–[9], [10]–[13], snoring signal [14], [15], respiratory sound signal [16], thoracic effort signal [17], EEG [18] and combined signals [1], [19] have been proposed for OSA detection.”
MethodClinical applications of artificial intelligence in sleep medicine: A sleep clinician’s perspective
Bandyopadhyay, A., & Goldstein, C. (2023) · Sleep And Breathing · doi:10.1007/s11325-022-02592-4 · Cited by 108
Obstructive Sleep Apnea Screening Using a Piezo-Electric Sensor
Erdenebayar, U., Park, J.-U., Jeong, P., & Lee, K.-J. (2017) · Journal of Korean Medical Science · doi:10.3346/jkms.2017.32.6.893 · Cited by 31
Metadata
- Authors
- Azarbarzin, A., & Moussavi, Z. M. K.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2011-05
- Volume
- 58
- Issue
- 5
- Pages
- 1156-1162
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2172119180
- Cited by
- 114
- References
- 8
- FWCI
- 3.69
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.