Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 214

The DOI matches its Crossref record.

Equivalent Pulse Parameters for Electroporation

Open access
Pucihar, G., Krmelj, J., Reberšek, M., Napotnik, T., Miklavčič, D.·2011·IEEE Transactions on Biomedical Engineering

Abstract

Electroporation-based applications require the use of specific pulse parameters for a successful outcome. When recommended values of pulse parameters cannot be set, similar outcomes can be obtained by using equivalent pulse parameters. We determined the relations between the amplitude and duration/number of pulses resulting in the same fraction of electroporated cells. Pulse duration was varied from 150 ns to 100 ms, and the number of pulses from 1 to 128. Fura 2-AM was used to determine electroporation of cells to Ca(2+). With longer pulses or higher number of pulses, lower amplitudes are needed for the same fraction of electroporated cells. The expression derived from the model of electroporation could describe the measured data on the whole interval of pulse durations. In a narrower range (0.1-100 ms), less complex, logarithmic or power functions could be used instead. The relation between amplitude and number of pulses could best be described with a power function or an exponential function. We show that relatively simple two-parameter power or logarithmic functions are useful when equivalent pulse parameters for electroporation are sought. Such mathematical relations between pulse parameters can be important in planning of electroporation-based treatments, such as electrochemotherapy and nonthermal irreversible electroporation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.2011.2167232

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Pucihar, G., Krmelj, J., Reberšek, M., Napotnik, T., & Miklavčič, D.
Venue
IEEE Transactions on Biomedical Engineering
Published
2011-11
Volume
58
Issue
11
Pages
3279-3288
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W2140332412
Cited by
214
References
0
FWCI
8.76
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.