Automated Prediction of the Apnea-Hypopnea Index from Nocturnal Oximetry Recordings
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Nocturnal polysomnography (PSG) is the gold-standard for sleep apnea-hypopnea syndrome (SAHS) diagnosis. It provides the value of the apnea-hypopnea index (AHI), which is used to evaluate SAHS severity. However, PSG is costly, complex, and time-consuming. We present a novel approach for automatic estimation of the AHI from nocturnal oxygen saturation (SaO(2)) recordings and the results of an assessment study designed to characterize its performance. A set of 240 SaO(2) signals was available for the assessment study. The data were divided into training (96 signals) and test (144 signals) sets for model optimization and validation, respectively. Fourteen time-domain and frequency-domain features were used to quantify the effect of SAHS on SaO(2) recordings. Regression analysis was performed to estimate the functional relationship between the extracted features and the AHI. Multiple linear regression (MLR) and multilayer perceptron (MLP) neural networks were evaluated. The MLP algorithm achieved the highest performance with an intraclass correlation coefficient (ICC) of 0.91. The proposed MLP-based method could be used as an accurate and cost-effective procedure for SAHS diagnosis in the absence of PSG.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intraclass correlations: Uses in assessing rater reliability.
Shrout, P. E., & Fleiss, J. L. (1979) · Psychological Bulletin · doi:10.1037/0033-2909.86.2.420 · Cited by 24,532
Approximation capabilities of multilayer feedforward networks
Hornik, K. (1991) · Neural Networks · doi:10.1016/0893-6080(91)90009-t · Cited by 6,091
Epidemiology of Obstructive Sleep Apnea: A Population Health Perspective
Young, T., Peppard, P. E., & Gottlieb, D. J. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.2109080 · Cited by 4,244 · cited 1×
“Epidemiological data support the finding that SAHS may have a role in the initiation or progression of diverse respiratory, cardiovascular, and cerebrovascular diseases [1], [2].”
BackgroundYoung, T., Evans, L., Finn, L., & Palta, M. (1997) · Sleep · doi:10.1093/sleep/20.9.705 · Cited by 1,765
Collop, N. A., Anderson, W. M., Boehlecke, B., Claman, D., Goldberg, R., Gottlieb, D. J., Hudgel, D., Sateia, M., Schwab, R., & Portable Monitoring Task Force of the American Academy of Sleep Medicine (2007) · Journal of Clinical Sleep Medicine · doi:10.5664/jcsm.27032 · Cited by 1,550
Cited by
Sleep apnea: a review of diagnostic sensors, algorithms, and therapies
Shokoueinejad, M., Fernandez, C., Carroll, E., Wang, F., Levin, J., Rusk, S., Glattard, N., Mulchrone, A., Zhang, X., Xie, A., et al. (2017) · Physiological Measurement · doi:10.1088/1361-6579/aa6ec6 · Cited by 64
O’Mahony, A. M., Garvey, J. F., & McNicholas, W. T. (2020) · Journal of Thoracic Disease · doi:10.21037/jtd-sleep-2020-003 · Cited by 45
Andrés-Blanco, A. M., Álvarez, D., Crespo, A., Arroyo, C. A., Cerezo-Hernández, A., Gutiérrez-Tobal, G. C., Hornero, R., & del Campo, F. (2017) · PLOS ONE · doi:10.1371/journal.pone.0188094 · Cited by 28
Self-citationGetting More from the Sleep Recording
McNicholas, W. T. (2021) · Sleep Medicine Clinics · doi:10.1016/j.jsmc.2021.08.001 · Cited by 3
Metadata
- Authors
- Marcos, J. V., Hornero, R., Álvarez, D., Aboy, M., & Del Campo, F.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2012-01
- Volume
- 59
- Issue
- 1
- Pages
- 141-149
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2019664248
- Cited by
- 61
- References
- 5
- FWCI
- 1.93
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.