CoChat

A Wearable Cardiac Monitor for Long-Term Data Acquisition and Analysis

Open access
Winokur, Eric S., Delano, Maggie K., Sodini, Charles G. · 2013 · IEEE Transactions on Biomedical Engineering
Cited by 62

The DOI matches its Crossref record.

Abstract

A low-power wearable ECG monitoring system has been developed entirely from discrete electronic components and a custom PCB. This device removes all loose wires from the system and minimizes the footprint on the user. The monitor consists of five electrodes, which allow a cardiologist to choose from a variety of possible projections. Clinical tests to compare our wearable monitor with a commercial clinical ECG recorder are conducted on ten healthy adults under different ambulatory conditions, with nine of the datasets used for analysis. Data from both monitors were synchronized and annotated with PhysioNet's waveform viewer WAVE (physionet.org) [1]. All gold standard annotations are compared to the results of the WQRS detection algorithm [2] provided by PhysioNet. QRS sensitivity and QRS positive predictability are extracted from both monitors to validate the wearable monitor.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.2012.2217958

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 62

Metadata

Authors
Winokur, E. S., Delano, M. K., & Sodini, C. G.
Venue
IEEE Transactions on Biomedical Engineering
Published
2013-01
Volume
60
Issue
1
Pages
189-192
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W2037324433
Cited by
62
References
0
FWCI
2.69
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A Wearable Cardiac Monitor for Long-Term Data Acquisition and Analysis. https://app.cochat.ai/papers/10.1109/tbme.2012.2217958
The paper
Winokur, E. S., Delano, M. K., & Sodini, C. G. (2013). A Wearable Cardiac Monitor for Long-Term Data Acquisition and Analysis. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2012.2217958

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.