The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
The Use of Ensemble Empirical Mode Decomposition With Canonical Correlation Analysis as a Novel Artifact Removal Technique
Abstract
Biosignal measurement and processing is increasingly being deployed in ambulatory situations particularly in connected health applications. Such an environment dramatically increases the likelihood of artifacts which can occlude features of interest and reduce the quality of information available in the signal. If multichannel recordings are available for a given signal source, then there are currently a considerable range of methods which can suppress or in some cases remove the distorting effect of such artifacts. There are, however, considerably fewer techniques available if only a single-channel measurement is available and yet single-channel measurements are important where minimal instrumentation complexity is required. This paper describes a novel artifact removal technique for use in such a context. The technique known as ensemble empirical mode decomposition with canonical correlation analysis (EEMD-CCA) is capable of operating on single-channel measurements. The EEMD technique is first used to decompose the single-channel signal into a multidimensional signal. The CCA technique is then employed to isolate the artifact components from the underlying signal using second-order statistics. The new technique is tested against the currently available wavelet denoising and EEMD-ICA techniques using both electroencephalography and functional near-infrared spectroscopy data and is shown to produce significantly improved results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, N. E., Shen, Z., Long, S. R., Wu, M. C., Shih, H. H., Zheng, Q., Yen, N.-C., Tung, C. C., & Liu, H. H. (1998) · Proceedings of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rspa.1998.0193 · Cited by 23,564
Daubechies, I. (1992) · doi:10.1137/1.9781611970104 · Cited by 15,979
Daubechies, I., & Heil, C. (1992) · Computers in Physics · doi:10.1063/1.4823127 · Cited by 15,631
An Introduction to Multivariate Statistical Analysis
Muirhead, R. J., & Anderson, T. W. (1986) · Journal of Business & Economic Statistics · doi:10.2307/1391399 · Cited by 9,082
An Information-Maximization Approach to Blind Separation and Blind Deconvolution
Bell, A. J., & Sejnowski, T. J. (1995) · Neural Computation · doi:10.1162/neco.1995.7.6.1129 · Cited by 8,986
ENSEMBLE EMPIRICAL MODE DECOMPOSITION: A NOISE-ASSISTED DATA ANALYSIS METHOD
WU, Z., & HUANG, N. E. (2009) · Advances in Adaptive Data Analysis · doi:10.1142/s1793536909000047 · Cited by 8,715
RELATIONS BETWEEN TWO SETS OF VARIATES
HOTELLING, H. (1936) · Biometrika · doi:10.1093/biomet/28.3-4.321 · Cited by 5,263
Independent Component Analysis
Hyvärinen, A., Karhunen, J., & Oja, E. (2001) · Wiley eBooks · doi:10.1002/0471221317 · Cited by 5,007
A Fast Fixed-Point Algorithm for Independent Component Analysis
Hyvärinen, A., & Oja, E. (1997) · Neural Computation · doi:10.1162/neco.1997.9.7.1483 · Cited by 3,391
Lee, T.-W., Girolami, M., & Sejnowski, T. J. (1999) · Neural Computation · doi:10.1162/089976699300016719 · Cited by 1,967
Relations Between Two Sets of Variates
Hotelling, H. (1936) · Biometrika · doi:10.2307/2333955 · Cited by 1,645
An Introduction to Multivariate Statistical Analysis
(2004) · Technometrics · doi:10.1198/tech.2004.s754 · Cited by 1,605
Recognizing faces with PCA and ICA
Draper, B. A., Baek, K., Bartlett, M. S., & Beveridge, J. R. (2003) · Computer Vision and Image Understanding · doi:10.1016/s1077-3142(03)00077-8 · Cited by 549
Canonical Correlation Analysis Applied to Remove Muscle Artifacts From the Electroencephalogram
Clercq, W. D., Vergult, A., Vanrumste, B., Van Paesschen, W., & Van Huffel, S. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.879459 · Cited by 522
Independent component analysis for biomedical signals
James, C. J., & Hesse, C. W. (2005) · Physiological Measurement · doi:10.1088/0967-3334/26/1/r02 · Cited by 494
Mijović, B., De Vos, M., Gligorijević, I., Taelman, J., & Van Huffel, S. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2051440 · Cited by 382
Blind Source Separation and Independent Component Analysis: A Review
Lee, S.-Y. (2005) · International Conference on Neural Information Processing · Cited by 374
Artifact Removal in Physiological Signals—Practices and Possibilities
Sweeney, K. T., Ward, T. E., & McLoone, S. F. (2012) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2012.2188536 · Cited by 361
Self-citationLearning multidimensional signal processing
Knutsson, H., Borga, M., & Landelius, T. (2002) · Proceedings. Fourteenth International Conference on Pattern Recognition (Cat. No.98EX170) · doi:10.1109/icpr.1998.711968 · Cited by 173
Motion Artifact Removal for Functional Near Infrared Spectroscopy: A Comparison of Methods
Robertson, F. C., Douglas, T. S., & Meintjes, E. M. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2038667 · Cited by 150
A Methodology for Validating Artifact Removal Techniques for Physiological Signals
Sweeney, K. T., Ayaz, H., Ward, T. E., İzzetoğlu, M., McLoone, S., & Onaral, B. (2012) · IEEE Transactions on Information Technology in Biomedicine · doi:10.1109/titb.2012.2207400 · Cited by 138
Self-citationKumar, P. S., Arumuganathan, R., Sivakumar, K., & Vimal, C. (2008) · Cited by 120
Single Channel Wireless EEG: Proposed Application in Train Drivers
Ridwan, S. D., Thompson, R. A., Jap, B. T., Lal, S., & Fischer, P. (2008) · International Conference on Broadband Communications, Information Technology & Biomedical Applications · doi:10.1109/broadcom.2008.69 · Cited by 19
Cited by
EEG artifact removal—state-of-the-art and guidelines
Urigüen, J. A., & Garcia-Zapirain, B. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/3/031001 · Cited by 963
Removal of Artifacts from EEG Signals: A Review
Jiang, X., Bian, G.-B., & Tian, Z. (2019) · Sensors · doi:10.3390/s19050987 · Cited by 826
Methods for artifact detection and removal from scalp EEG: A review
Islam, M. K., Rastegarnia, A., & Yang, Z. (2016) · Neurophysiologie Clinique/Clinical Neurophysiology · doi:10.1016/j.neucli.2016.07.002 · Cited by 457
Wearable, Wireless EEG Solutions in Daily Life Applications: What are we Missing?
Mihajlovic, V., Grundlehner, B., Vullers, R., & Penders, J. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2328317 · Cited by 289
Trends in EEG-BCI for daily-life: Requirements for artifact removal
Minguillon, J., Lopez-Gordo, M. A., & Pelayo, F. (2017) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2016.09.005 · Cited by 289
Metadata
- Authors
- Sweeney, K. T., McLoone, S. F., & Ward, T. E.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2013-01
- Volume
- 60
- Issue
- 1
- Pages
- 97-105
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W1971981854
- Cited by
- 300
- References
- 23
- FWCI
- 7.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.