A Hybrid BCI System Combining P300 and SSVEP and Its Application to Wheelchair Control
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
In this paper, a hybrid brain-computer interface (BCI) system combining P300 and steady-state visual evoked potential (SSVEP) is proposed to improve the performance of asynchronous control. The four groups of flickering buttons were set in the graphical user interface. Each group contained one large button in the center and eight small buttons around it, all of which flashed at a fixed frequency (e.g., 7.5 Hz) to evoke SSVEP. At the same time, the four large buttons of the four groups were intensified through shape and color changes in a random order to produce P300 potential. During the control state, the user focused on a desired group of buttons (target buttons) to evoke P300 potential and SSVEP, simultaneously. Discrimination between the control and idle states was based on the detection of both P300 and SSVEP on the same group of buttons. As an application, this method was used to produce a "go/stop" command in real-time wheelchair control. Several experiments were conducted, and data analysis results showed that combining P300 potential and SSVEP significantly improved the performance of the BCI system in terms of detection accuracy and response time.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Event-related EEG/MEG synchronization and desynchronization: basic principles
Pfurtscheller, G., & Lopes da Silva, F. H. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00141-8 · Cited by 7,328
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228
Brain-computer interface technology: a review of the first international meeting
Wolpaw, J. R., Birbaumer, N., Heetderks, W. J., McFarland, D. J., Peckham, P. H., Schalk, G., Donchin, E., Quatrano, L. A., Robinson, C. J., & Vaughan, T. M. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/tre.2000.847807 · Cited by 2,324
Design and implementation of a brain-computer interface with high transfer rates
Cheng, M., Gao, X., Gao, S., & Xu, D. (2002) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2002.803536 · Cited by 818
Brain-computer interfaces based on the steady-state visual-evoked response
Middendorf, M., McMillan, G., Calhoun, G., & Jones, K. S. (2000) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.847819 · Cited by 685
How many people are able to control a P300-based brain-computer interface (BCI)?
Guger, C., Daban, S., Sellers, E., Holzner, C., Krausz, G., Carabalona, R., Gramatica, F., & Edlinger, G. (2009) · Neuroscience Letters · doi:10.1016/j.neulet.2009.06.045 · Cited by 652
Pfurtscheller, G. (2010) · Frontiers in Neuroscience · doi:10.3389/fnpro.2010.00003 · Cited by 625
Control of an Electrical Prosthesis With an SSVEP-Based BCI
Muller-Putz, G. R., & Pfurtscheller, G. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.897815 · Cited by 589
Multiple Channel Detection of Steady-State Visual Evoked Potentials for Brain-Computer Interfaces
Friman, O., Volosyak, I., & Graser, A. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.889160 · Cited by 541
Cited by
Brain computer interface: control signals review
Ramadan, R. A., & Vasilakos, A. V. (2017) · Neurocomputing · doi:10.1016/j.neucom.2016.10.024 · Cited by 551
Rashid, M., Sulaiman, N., P. P. Abdul Majeed, A., Musa, R. M., Ab. Nasir, A. F., Bari, B. S., & Khatun, S. (2020) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2020.00025 · Cited by 506
EEG Based Emotion Recognition by Combining Functional Connectivity Network and Local Activations
Li, P., Liu, H., Si, Y., Li, C., Li, F., Zhu, X., Huang, X., Zeng, Y., Yao, D., Zhang, Y., et al. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2897651 · Cited by 396
EEG source imaging enhances the decoding of complex right-hand motor imagery tasks
Edelman, B. J., Baxter, B., & He, B. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2467312 · Cited by 370
Trends in EEG-BCI for daily-life: Requirements for artifact removal
Minguillon, J., Lopez-Gordo, M. A., & Pelayo, F. (2017) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2016.09.005 · Cited by 289
Metadata
- Authors
- Li, Y., Pan, J., Wang, F., & Yu, Z.
- Affiliations
- South China University of Technology (CN)
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2013-11
- Volume
- 60
- Issue
- 11
- Pages
- 3156-3166
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W1967545169
- Cited by
- 421
- References
- 35
- Citations by year
- 2026: 11 · 2025: 37 · 2024: 39 · 2023: 38 · 2022: 43 · 2021: 41 · 2020: 36 · 2019: 35 · 2018: 37 · 2017: 33 · 2016: 30 · 2015: 18 · 2014: 21 · 2013: 1
- FWCI
- 12.75
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Biomedical Engineering (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Physical Sciences › Computer Science › Human-Computer Interaction › Gaze Tracking and Assistive Technology
- Physical Sciences › Computer Science › Artificial Intelligence › Emotion and Mood Recognition
- Keywords
- hybrid brain-computer interface, P300, steady-state visual evoked potentials, wheelchair control, asynchronous control, flicker paradigm, real-time control, detection accuracy, response time
- MeSH terms
- Adult, Biomedical Engineering, Electroencephalography, Evoked Potentials, Visual, Humans, ROC Curve, Signal Processing, Computer-Assisted, User-Computer Interface, Wheelchairs, Reproducibility of Results, Event-Related Potentials, P300, Young Adult, Brain-Computer Interfaces
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.