The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Microwave-Based Stroke Diagnosis Making Global Prehospital Thrombolytic Treatment Possible
Open accessAbstract
Here, we present two different brain diagnostic devices based on microwave technology and the associated two first proof-of-principle measurements that show that the systems can differentiate hemorrhagic from ischemic stroke in acute stroke patients, as well as differentiate hemorrhagic patients from healthy volunteers. The system was based on microwave scattering measurements with an antenna system worn on the head. Measurement data were analyzed with a machine-learning algorithm that is based on training using data from patients with a known condition. Computer tomography images were used as reference. The detection methodology was evaluated with the leave-one-out validation method combined with a Monte Carlo-based bootstrap step. The clinical motivation for this project is that ischemic stroke patients may receive acute thrombolytic treatment at hospitals, dramatically reducing or abolishing symptoms. A microwave system is suitable for prehospital use, and therefore has the potential to allow significantly earlier diagnosis and treatment than today.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Introduction to the Bootstrap
Efron, B., & Tibshirani, R. J. (1994) · doi:10.1201/9780429246593 · Cited by 40,500
The Elements of Statistical Learning: Data Mining, Inference, and Prediction
John Lu, Z. Q. (2010) · Journal of the Royal Statistical Society Series A: Statistics in Society · doi:10.1111/j.1467-985x.2010.00646_6.x · Cited by 12,390
Tissue Plasminogen Activator for Acute Ischemic Stroke
(1995) · New England Journal of Medicine · doi:10.1056/nejm199512143332401 · Cited by 11,654
Receiver-operating characteristic (ROC) plots: a fundamental evaluation tool in clinical medicine
Zweig, M. H., & Campbell, G. (1993) · Clinical Chemistry · doi:10.1093/clinchem/39.4.561 · Cited by 6,569
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/002 · Cited by 4,270
Guidelines for Management of Ischaemic Stroke and Transient Ischaemic Attack 2008
(2008) · Cerebrovascular Diseases · doi:10.1159/000131083 · Cited by 2,489
The economic cost of brain disorders in Europe
Olesen, J., Gustavsson, A., Svensson, M., Wittchen, H. ‐., Jönsson, B., on behalf of the CDBE2010 study group, & the European Brain Council (2012) · European Journal of Neurology · doi:10.1111/j.1468-1331.2011.03590.x · Cited by 1,481
Scharf, L. L., & Friedlander, B. (1994) · IEEE Transactions on Signal Processing · doi:10.1109/78.301849 · Cited by 958
Adams, H. P., del Zoppo, G., Alberts, M. J., Bhatt, D. L., Brass, L., Furlan, A., Grubb, R. L., Higashida, R. T., Jauch, E. C., Kidwell, C., et al. (2007) · Circulation · doi:10.1161/circulationaha.107.181486 · Cited by 904
Subspace methods of pattern recognition
(1984) · Signal Processing · doi:10.1016/0165-1684(84)90028-8 · Cited by 791
Cited by
On the Opportunities and Challenges in Microwave Medical Sensing and Imaging
Chandra, R., Zhou, H., Balasingham, I., & Narayanan, R. M. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2432137 · Cited by 418
La Gioia, A., Porter, E., Merunka, I., Shahzad, A., Salahuddin, S., Jones, M., & O’Halloran, M. (2018) · Diagnostics · doi:10.3390/diagnostics8020040 · Cited by 297
Metadata
- Authors
- Persson, M., Fhager, A., Trefna, H. D., Yu, Y., McKelvey, T., Pegenius, G., Karlsson, J.-E., & Elam, M.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2014-11
- Volume
- 61
- Issue
- 11
- Pages
- 2806-2817
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2023279849
- Cited by
- 380
- References
- 24
- FWCI
- 14.73
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.