An Anatomically Detailed Arterial Network Model for One-Dimensional Computational Hemodynamics
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Simulation platforms are increasingly becoming complementary tools for cutting-edge cardiovascular research. The interplay among structural properties of the arterial wall, morphometry, anatomy, wave propagation phenomena, and ultimately, cardiovascular diseases continues to be poorly understood. Accurate models are powerful tools to shed light on these open problems. We developed an anatomically detailed computational model of the arterial vasculature to conduct 1-D blood flow simulations to serve as simulation infrastructure to aid cardiovascular research. An average arterial vasculature of a man was outlined in 3-D space to serve as geometrical substrate for the mathematical model. The architecture of this model comprises almost every arterial vessel acknowledged in the medical/anatomical literature, with a resolution down to the luminal area of perforator arteries. Over 2000 arterial vessels compose the model. Anatomical, physiological, and mechanical considerations were employed for the set up of model parameters and to determine criteria for blood flow distribution. Computational fluid dynamics was used to simulate blood flow and wave propagation phenomena in such arterial network. A sensitivity analysis was developed to unveil the contributions of model parameters to the conformation of the pressure waveforms. In addition, parameters were modified to target model to a patient-specific scenario. On the light of the knowledge domain, we conclude that the present model features excellent descriptive and predictive capabilities in both patient-generic and patient-specific cases, presenting a new step toward integrating an unprecedented anatomical description, morphometric, and simulations data to help in understanding complex arterial blood flow phenomena and related cardiovascular diseases.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analog studies of the human systemic arterial tree
Westerhof, N., Bosman, F., De Vries, C. J., & Noordergraaf, A. (1969) · Journal of Biomechanics · doi:10.1016/0021-9290(69)90024-4 · Cited by 684 · cited 1×
“From pioneer works studying the basic theoretical ingredients [15]–[19], going through the early developments of topological descriptions of the CVS [20]–[25], subsequent improvements and alternatives [26]–[30], and finally, reaching incontestable in vitro validations and in vivo verifications [31]–[35], as well as in…”
BackgroundAnliker, M., Rockwell, R. L., & Ogden, E. (1971) · Zeitschrift für angewandte Mathematik und Physik ZAMP · doi:10.1007/bf01591407 · Cited by 202
Genesis of the normal and abnormal arterial pulse
Vlachopoulos, C., & O'Rourke, M. (2000) · Current Problems in Cardiology · doi:10.1067/mcd.2000.104057 · Cited by 125
Stettler, J. C., Niederer, P., & Anliker, M. (1981) · Annals of Biomedical Engineering · doi:10.1007/bf02363533 · Cited by 107
Stettler, J. C., Niederer, P., Anliker, M., & Casty, M. (1981) · Annals of Biomedical Engineering · doi:10.1007/bf02363534 · Cited by 35 · cited 1×
“…early developments of topological descriptions of the CVS [20], [21], [22], [23], [24], [25], subsequent improvements and alternatives [26], [27], [28], [29], [30], and finally reaching incontestable in-vitro validations and in-vivo verifications [31], [32], [33], [34], [35] as well as in-silico…”
Metadata
- Authors
- Blanco, P. J., Watanabe, S. M., Passos, M. A. R. F., Lemos, P. A., & Feijoo, R. A.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2015-02
- Volume
- 62
- Issue
- 2
- Pages
- 736-753
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W1984116661
- Cited by
- 163
- References
- 5
- FWCI
- 4.97
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.