Enhanced Motor Imagery Training Using a Hybrid BCI With Feedback
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
GOAL: Motor imagery-related mu/beta rhythms, which can be voluntarily modulated by subjects, have been widely used in EEG-based brain computer interfaces (BCIs). Moreover, it has been suggested that motor imagery-specific EEG differences can be enhanced by feedback training. However, the differences observed in the EEGs of naive subjects are typically not sufficient to provide reliable EEG control and thus result in unintended feedback. Such feedback can frustrate subjects and impede training. In this study, a hybrid BCI paradigm combining motor imagery and steady-state visually evoked potentials (SSVEPs) has been proposed to provide effective continuous feedback for motor imagery training. METHODS: During the initial training sessions, subjects must focus on flickering buttons to evoke SSVEPs as they perform motor imagery tasks. The output/feedback of the hybrid BCI is based on hybrid features consisting of motor imagery- and SSVEP-related brain signals. In this context, the SSVEP plays a more important role than motor imagery in generating feedback. As the training progresses, the subjects can gradually decrease their visual attention to the flickering buttons, provided that the feedback is still effective. In this case, the feedback is mainly based on motor imagery. RESULTS: Our experimental results demonstrate that subjects generate distinguishable brain patterns of hand motor imagery after only five training sessions lasting approximately 1.5 h each. CONCLUSION: The proposed hybrid feedback paradigm can be used to enhance motor imagery training. SIGNIFICANCE: This hybrid BCI system with feedback can effectively identify the intentions of the subjects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
Event-related EEG/MEG synchronization and desynchronization: basic principles
Pfurtscheller, G., & Lopes da Silva, F. H. (1999) · Clinical Neurophysiology · doi:10.1016/s1388-2457(99)00141-8 · Cited by 7,328
Farwell, L. A., & Donchin, E. (1988) · Electroencephalography and Clinical Neurophysiology · doi:10.1016/0013-4694(88)90149-6 · Cited by 3,228
Optimizing Spatial filters for Robust EEG Single-Trial Analysis
Blankertz, B., Tomioka, R., Lemm, S., Kawanabe, M., & Muller, K.-R. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2008.4408441 · Cited by 2,080 · cited 2×
“The CSP filters were trained using the calibration data obtained from each training session, which indicated the weights of the original signals for obtaining optimally discriminative projected variances [32].”
BackgroundMethodControl of a two-dimensional movement signal by a noninvasive brain-computer interface in humans
Wolpaw, J. R., & McFarland, D. J. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0403504101 · Cited by 1,512
Neurophysiological predictor of SMR-based BCI performance
Blankertz, B., Sannelli, C., Halder, S., Hammer, E. M., Kübler, A., Müller, K.-R., Curio, G., & Dickhaus, T. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2010.03.022 · Cited by 674
LaFleur, K., Cassady, K., Doud, A., Shades, K., Rogin, E., & He, B. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/4/046003 · Cited by 583
How many people are able to operate an EEG-based brain-computer interface (BCI)?
Guger, C., Edlinger, G., Harkam, W., Niedermayer, I., & Pfurtscheller, G. (2003) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2003.814481 · Cited by 526
The Berlin brain-computer Interface: accurate performance from first-session in BCI-naive subjects
Blankertz, B., Losch, F., Krauledat, M., Dornhege, G., Curio, G., & Muller, K.-R. (2008) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2008.923152 · Cited by 338
Cited by
A comprehensive review of EEG-based brain–computer interface paradigms
Abiri, R., Borhani, S., Sellers, E. W., Jiang, Y., & Zhao, X. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/aaf12e · Cited by 946
EEG-Based Brain-Computer Interfaces Using Motor-Imagery: Techniques and Challenges
Padfield, N., Zabalza, J., Zhao, H., Masero, V., & Ren, J. (2019) · Sensors · doi:10.3390/s19061423 · Cited by 596
Hong, K.-S., & Khan, M. J. (2017) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2017.00035 · Cited by 267
Multi-kernel extreme learning machine for EEG classification in brain-computer interfaces
Zhang, Y., Wang, Y., Zhou, G., Jin, J., Wang, B., Wang, X., & Cichocki, A. (2018) · Expert Systems with Applications · doi:10.1016/j.eswa.2017.12.015 · Cited by 255
Self-citationLi, Y., Pan, J., Long, J., Yu, T., Wang, F., Yu, Z., & Wu, W. (2016) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2469106 · Cited by 117
“In [29], a multimodal BCI combining MI and SSVEPs was proposed to provide positive feedback and facilitate MI training.”
MethodSelf-citation
Metadata
- Authors
- Yu, T., Xiao, J., Wang, F., Zhang, R., Gu, Z., Cichocki, A., & Li, Y.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2015-07
- Volume
- 62
- Issue
- 7
- Pages
- 1706-1717
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2076346683
- Cited by
- 124
- References
- 9
- FWCI
- 6.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.