Cutaneous Feedback of Fingertip Deformation and Vibration for Palpation in Robotic Surgery
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
Despite its expected clinical benefits, current teleoperated surgical robots do not provide the surgeon with haptic feedback largely because grounded forces can destabilize the system's closed-loop controller. This paper presents an alternative approach that enables the surgeon to feel fingertip contact deformations and vibrations while guaranteeing the teleoperator's stability. We implemented our cutaneous feedback solution on an Intuitive Surgical da Vinci Standard robot by mounting a SynTouch BioTac tactile sensor to the distal end of a surgical instrument and a custom cutaneous display to the corresponding master controller. As the user probes the remote environment, the contact deformations, dc pressure, and ac pressure (vibrations) sensed by the BioTac are directly mapped to input commands for the cutaneous device's motors using a model-free algorithm based on look-up tables. The cutaneous display continually moves, tilts, and vibrates a flat plate at the operator's fingertip to optimally reproduce the tactile sensations experienced by the BioTac. We tested the proposed approach by having eighteen subjects use the augmented da Vinci robot to palpate a heart model with no haptic feedback, only deformation feedback, and deformation plus vibration feedback. Fingertip deformation feedback significantly improved palpation performance by reducing the task completion time, the pressure exerted on the heart model, and the subject's absolute error in detecting the orientation of the embedded plastic stick. Vibration feedback significantly improved palpation performance only for the seven subjects who dragged the BioTac across the model, rather than pressing straight into it.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hand movements: A window into haptic object recognition
Lederman, S. J., & Klatzky, R. L. (1987) · Cognitive Psychology · doi:10.1016/0010-0285(87)90008-9 · Cited by 2,016
Cutaneous force feedback as a sensory subtraction technique in haptics
Prattichizzo, D., Pacchierotti, C., & Rosati, G. (2012) · IEEE Transactions on Haptics · doi:10.1109/toh.2012.15 · Cited by 172
Self-citationPerformance measurement in scaled teleoperation for microsurgery
Salcudean, S. E., Ku, S., & Bell, G. (1997) · Lecture Notes in Computer Science · doi:10.1007/bfb0029304 · Cited by 96 · cited 1×
“It has been shown to enhance surgeon performance in a wide range of applications including microneedle positioning [10], telerobotic catheter insertion [11], suturing simulation [12], cardiothoracic procedures [13], and cell injection [14].”
Background
Cited by
Wearable Haptic Systems for the Fingertip and the Hand: Taxonomy, Review, and Perspectives
Pacchierotti, C., Sinclair, S., Solazzi, M., Frisoli, A., Hayward, V., & Prattichizzo, D. (2017) · IEEE Transactions on Haptics · doi:10.1109/toh.2017.2689006 · Cited by 825
Self-citationHaptics: The Present and Future of Artificial Touch Sensation
Culbertson, H., Schorr, S. B., & Okamura, A. M. (2018) · Annual Review of Control, Robotics, and Autonomous Systems · doi:10.1146/annurev-control-060117-105043 · Cited by 431
Baldi, T. L., Scheggi, S., Meli, L., Mohammadi, M., & Prattichizzo, D. (2017) · IEEE Transactions on Human-Machine Systems · doi:10.1109/thms.2017.2720667 · Cited by 96
Self-citationSoft Wearable Skin-Stretch Device for Haptic Feedback Using Twisted and Coiled Polymer Actuators
Chossat, J.-B., Chen, D. K. Y., Park, Y.-L., & Shull, P. B. (2019) · IEEE Transactions on Haptics · doi:10.1109/toh.2019.2943154 · Cited by 73
Metadata
- Authors
- Pacchierotti, C., Prattichizzo, D., & Kuchenbecker, K. J.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2016-02
- Volume
- 63
- Issue
- 2
- Pages
- 278-287
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2241992751
- Cited by
- 235
- References
- 3
- FWCI
- 24.85
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.