The DOI matches its Crossref record; 67 of the 67 references it cites were found in a registry or an index.
Full-Body Musculoskeletal Model for Muscle-Driven Simulation of Human Gait
Open accessAbstract
OBJECTIVE: Musculoskeletal models provide a non-invasive means to study human movement and predict the effects of interventions on gait. Our goal was to create an open-source 3-D musculoskeletal model with high-fidelity representations of the lower limb musculature of healthy young individuals that can be used to generate accurate simulations of gait. METHODS: Our model includes bony geometry for the full body, 37 degrees of freedom to define joint kinematics, Hill-type models of 80 muscle-tendon units actuating the lower limbs, and 17 ideal torque actuators driving the upper body. The model's musculotendon parameters are derived from previous anatomical measurements of 21 cadaver specimens and magnetic resonance images of 24 young healthy subjects. We tested the model by evaluating its computational time and accuracy of simulations of healthy walking and running. RESULTS: Generating muscle-driven simulations of normal walking and running took approximately 10 minutes on a typical desktop computer. The differences between our muscle-generated and inverse dynamics joint moments were within 3% (RMSE) of the peak inverse dynamics joint moments in both walking and running, and our simulated muscle activity showed qualitative agreement with salient features from experimental electromyography data. CONCLUSION: These results suggest that our model is suitable for generating muscle-driven simulations of healthy gait. We encourage other researchers to further validate and apply the model to study other motions of the lower extremity. SIGNIFICANCE: The model is implemented in the open-source software platform OpenSim. The model and data used to create and test the simulations are freely available at https://simtk.org/home/full_body/, allowing others to reproduce these results and create their own simulations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
OpenSim: Open-Source Software to Create and Analyze Dynamic Simulations of Movement
Delp, S. L., Anderson, F. C., Arnold, A. S., Loan, P., Habib, A., John, C. T., Guendelman, E., & Thelen, D. G. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.901024 · Cited by 4,933
Self-citationGait Analysis: Normal and Pathological Function
(1992) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1992.03490220101046 · Cited by 3,875
Muscle and tendon: properties, models, scaling, and application to biomechanics and motor control.
Zajac, F. E. (1989) · PubMed · Cited by 3,021
An interactive graphics-based model of the lower extremity to study orthopaedic surgical procedures
Delp, S. L., Loan, J. P., Hoy, M. G., Zajac, F. E., Topp, E. L., & Rosen, J. M. (1990) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.102791 · Cited by 2,005
Self-citationNeptune, R. R., Kautz, S. A., & Zajac, F. E. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00105-1 · Cited by 1,132
Analysis of musculoskeletal systems in the AnyBody Modeling System
Damsgaard, M., Rasmussen, J., Christensen, S. T., Surma, E., & de Zee, M. (2006) · Simulation Modelling Practice and Theory · doi:10.1016/j.simpat.2006.09.001 · Cited by 1,031
Muscle Architecture of the Human Lower Limb
Wickiewicz, T. L., Roy, R. R., Powell, P. L., & Edgerton, V. R. (1983) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198310000-00042 · Cited by 928
A Model of the Lower Limb for Analysis of Human Movement
Arnold, E. M., Ward, S. R., Lieber, R. L., & Delp, S. L. (2010) · Annals of Biomedical Engineering · doi:10.1007/s10439-009-9852-5 · Cited by 859
Self-citationMuscle contributions to propulsion and support during running
Hamner, S. R., Seth, A., & Delp, S. L. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2010.06.025 · Cited by 851
Self-citationDifferential Geometry of Curves and Surfaces
Banchoff, T., & Lovett, S. (2016) · Chapman & Hall/CRC eBooks · doi:10.1201/b18913 · Cited by 836
Cited by
Seth, A., Hicks, J. L., Uchida, T. K., Habib, A., Dembia, C. L., Dunne, J. J., Ong, C. F., DeMers, M. S., Rajagopal, A., Millard, M., et al. (2018) · PLOS Computational Biology · doi:10.1371/journal.pcbi.1006223 · Cited by 1,322
Self-citationOpenCap: Human movement dynamics from smartphone videos
Uhlrich, S. D., Falisse, A., Kidziński, Ł., Muccini, J., Ko, M., Chaudhari, A. S., Hicks, J. L., & Delp, S. L. (2023) · PLOS Computational Biology · doi:10.1371/journal.pcbi.1011462 · Cited by 449
Self-citationHiasa, Y., Otake, Y., Takao, M., Ogawa, T., Sugano, N., & Sato, Y. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2940555 · Cited by 157
Erdemir, A., Mulugeta, L., Ku, J. P., Drach, A., Horner, M., Morrison, T. M., Peng, G. C. Y., Vadigepalli, R., Lytton, W. W., & Myers, J. G. (2020) · Journal of Translational Medicine · doi:10.1186/s12967-020-02540-4 · Cited by 118
Werling, K., Bianco, N. A., Raitor, M., Stingel, J., Hicks, J. L., Collins, S. H., Delp, S. L., & Liu, C. K. (2023) · PLOS ONE · doi:10.1371/journal.pone.0295152 · Cited by 65
Self-citationA Whole-Body Musculoskeletal Model of the Mouse
Tata Ramalingasetty, S., Danner, S. M., Arreguit, J., Markin, S. N., Rodarie, D., Kathe, C., Courtine, G., Rybak, I. A., & Ijspeert, A. J. (2021) · IEEE Access · doi:10.1109/access.2021.3133078 · Cited by 35
Construction and Application of Large-Scale Image Database in Orthopedic Surgery
Otake, Y., Takao, M., Yokota, F., Fukuda, N., Uemura, K., Sugano, N., & Sato, Y. (2018) · Computer Assisted Orthopaedic Surgery for Hip and Knee · doi:10.1007/978-981-10-5245-3_16 · Cited by 1
Metadata
- Authors
- Rajagopal, A., Dembia, C. L., DeMers, M. S., Delp, D. D., Hicks, J. L., & Delp, S. L.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2016-10
- Volume
- 63
- Issue
- 10
- Pages
- 2068-2079
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2470342634
- Cited by
- 1,053
- References
- 67
- FWCI
- 20.67
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.