The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Sockets for Limb Prostheses: A Review of Existing Technologies and Open Challenges
Open accessAbstract
In the prosthetics field, one of the most important bottlenecks is still the human-machine interface, namely the socket. Indeed, a large number of amputees still rejects prostheses or points out a low satisfaction level, due to a sub-optimal interaction between the socket and the residual limb tissues. The aim of this paper is to describe the main parameters (displacements, stress, volume fluctuations and temperature) affecting the stump-socket interface and reducing the comfort/stability of limb prostheses. In this review, a classification of the different socket types proposed in the literature is reported, together with an analysis of advantages and disadvantages of the different solutions, from multiple viewpoints. The paper then describes the technological solutions available to face an altered distribution of stresses on the residual limb tissues, volume fluctuations affecting the stump overtime and temperature variations affecting the residual tissues within the socket. The open challenges in this research field are highlighted and the possible future routes are discussed, towards the ambitious objective of achieving an advanced socket able to self-adapt in real-time to the complex interplay of factors affecting the stump, during both static and dynamic tasks.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimating the Prevalence of Limb Loss in the United States: 2005 to 2050
Ziegler-Graham, K., MacKenzie, E. J., Ephraim, P. L., Travison, T. G., & Brookmeyer, R. (2008) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2007.11.005 · Cited by 2,816
A review on 3D micro-additive manufacturing technologies
Vaezi, M., Seitz, H., & Yang, S. (2013) · The International Journal of Advanced Manufacturing Technology · doi:10.1007/s00170-012-4605-2 · Cited by 1,293
Gait velocity as a single predictor of adverse events in healthy seniors aged 75 years and older
Montero-Odasso, M., Schapira, M., Soriano, E. R., Varela, M., Kaplan, R., Camera, L. A., & Mayorga, L. M. (2005) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/60.10.1304 · Cited by 746
The prevalence and risk factors of falling and fear of falling among lower extremity amputees
Miller, W. C., Speechley, M., & Deathe, B. (2001) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.24295 · Cited by 642
Stiffening in Soft Robotics: A Review of the State of the Art
Manti, M., Cacucciolo, V., & Cianchetti, M. (2016) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2016.2582718 · Cited by 637
Importance of skin temperature in the regulation of sweating.
Nadel, E. R., Bullard, R. W., & Stolwijk, J. A. (1971) · Journal of Applied Physiology · doi:10.1152/jappl.1971.31.1.80 · Cited by 545
Energy expenditure and biomechanical characteristics of lower limb amputee gait:
Schmalz, T., Blumentritt, S., & Jarasch, R. (2002) · Gait & Posture · doi:10.1016/s0966-6362(02)00008-5 · Cited by 428
Bionic ankle–foot prosthesis normalizes walking gait for persons with leg amputation
Herr, H. M., & Grabowski, A. M. (2012) · Proceedings of the Royal Society B: Biological Sciences · doi:10.1098/rspb.2011.1194 · Cited by 391
Additive fabrication technologies applied to medicine and health care: a review
Giannatsis, J., & Dedoussis, V. (2009) · The International Journal of Advanced Manufacturing Technology · doi:10.1007/s00170-007-1308-1 · Cited by 389
Dillingham, T. R., Pezzin, L. E., MacKenzie, E. J., & Burgess, A. R. (2001) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/00002060-200108000-00003 · Cited by 385
Jiménez-Fabián, R., & Verlinden, O. (2012) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2011.11.018 · Cited by 313
Residual limb volume change: Systematic review of measurement and management
Sanders, J. E., & Fatone, S. (2011) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2010.09.0189 · Cited by 280
Pneumatic and hydraulic microactuators: a review
De Volder, M., & Reynaerts, D. (2010) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/20/4/043001 · Cited by 278
Active lower limb prosthetics: a systematic review of design issues and solutions
Windrich, M., Grimmer, M., Christ, O., Rinderknecht, S., & Beckerle, P. (2016) · BioMedical Engineering OnLine · doi:10.1186/s12938-016-0284-9 · Cited by 272
Zhao, X., & Liu, R. (2012) · Environment International · doi:10.1016/j.envint.2011.12.003 · Cited by 251
Hagberg, K., & Brånemark, R. (2009) · PubMed · Cited by 248
Improving the coefficient of performance of thermoelectric cooling systems: a review
Riffat, S. B., & Ma, X. (2004) · International Journal of Energy Research · doi:10.1002/er.991 · Cited by 242
A comparison of trans-tibial amputee suction and vacuum socket conditions
W. J. Board, Street, G. M., & Caspers, C. (2001) · Prosthetics and Orthotics International · doi:10.1080/03093640108726603 · Cited by 219
Ciuti, G., Ricotti, L., Menciassi, A., & Dario, P. (2015) · Sensors · doi:10.3390/s150306441 · Cited by 172
Self-citationAl-Fakih, E., Abu Osman, N. A., & Mahamd Adikan, F. R. (2012) · Sensors · doi:10.3390/s121012890 · Cited by 159
Sengeh, D. M., & Herr, H. (2013) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/jpo.0b013e31829be19c · Cited by 154
Klute, G. K., Berge, J. S., Biggs, W. T., Pongnumkul, S., Popović, Z., & Curless, B. (2011) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2011.05.019 · Cited by 140
Development and validation of a 3D-printed interfacial stress sensor for prosthetic applications
Laszczak, P., Jiang, L., Bader, D. L., et al. (2014) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2014.10.002 · Cited by 135
Finite element analysis of the amputated lower limb: A systematic review and recommendations
Dickinson, A., Steer, J. W., & Worsley, P. R. (2017) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2017.02.008 · Cited by 121
Rehabilitation in limb deficiency. 1. Gait and motion analysis
Czerniecki, J. M. (1996) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/s0003-9993(96)90236-1 · Cited by 105
Prevalence of heat and perspiration discomfort inside prostheses: Literature review
Ghoseiri, K., & Safari, R. (2014) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2013.06.0133 · Cited by 96
Prosthetic Liners for Lower Limb Amputees
Klute, G. K., Glaister, B. C., & Berge, J. S. (2010) · Prosthetics and Orthotics International · doi:10.3109/03093641003645528 · Cited by 96
Access to prosthetic devices in developing countries: Pathways and challenges
Marino, M., Pattni, S., Greenberg, M., Miller, A., Hocker, E., Ritter, S. C., & Mehta, K. (2015) · IEEE Global Humanitarian Technology Conference (GHTC) · doi:10.1109/ghtc.2015.7343953 · Cited by 96
The thermal conductivity of prosthetic sockets and liners
Klute, G. K., Rowe, G. I., Mamishev, A. V., & Ledoux, W. R. (2007) · Prosthetics and Orthotics International · doi:10.1080/03093640601042554 · Cited by 90
The Evolution of Upper Limb Prosthetic Socket Design
(2008) · doi:10.1097/jpo.0b013e31817d2f08 · Cited by 74
Design of lower limb prosthesis with contact pressure adjustment by MR fluid
Ogawa, A., Obinata, G., Kazunori, H. A. S. E., Dutta, A., & Nakagawa, M. (2008) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2008.4649157 · Cited by 63
Carrigan, W., Nothnagle, C., Savant, P., Gao, F., & Wijesundara, M. B. J. (2016) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob.2016.7523687 · Cited by 59
Trends and Challenges in Lower Limb Prosthesis
Kumar, P. K., Charan, M. U., & Kanagaraj, S. (2017) · IEEE Potentials · doi:10.1109/mpot.2016.2614756 · Cited by 48
Common skin pathology in LE prosthesis users
Highsmith, J. T., & Highsmith, M. J. (2007) · JAAPA · doi:10.1097/01720610-200711000-00018 · Cited by 45
Koehler-McNicholas, S. R., Lipschutz, R. D., & Gard, S. A. (2016) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2014.12.0311 · Cited by 41
SmartTemp Prosthetic Liner Significantly Reduces Residual Limb Temperature and Perspiration
Wernke, M. M., Schroeder, R. M., Kelley, C. T., Denune, J. A., & Colvin, J. M. (2015) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/jpo.0000000000000070 · Cited by 37
User experience of transtibial prosthetic liners: A systematic review
Richardson, A., & Dillon, M. P. (2016) · Prosthetics and Orthotics International · doi:10.1177/0309364616631343 · Cited by 33
Ghoseiri, K., Zheng, Y., Hing, L. L. T., Safari, R., & Leung, K. L. (2015) · Prosthetics and Orthotics International · doi:10.1177/0309364615588343 · Cited by 25
The Effect of Transfemoral Interface Design On Gait Speed and Risk of Falls
Kahle, J. T., Klenow, T. D., Sampson, W. J., & Highsmith, M. J. (2016) · Technology & Innovation · doi:10.21300/18.2-3.2016.167 · Cited by 21
Temperature measurement and control system for transtibial prostheses: Functional evaluation
Ghoseiri, K., Zheng, Y., Leung, K. L., Rahgozar, M., Aminian, G., Lee, T. H., & Safari, R. (2016) · Assistive Technology · doi:10.1080/10400435.2016.1225850 · Cited by 17
Sordo, G., & Lorenzelli, L. (2016) · Symposium on Design, Test, Integration and Packaging of MEMS/MOEMS · doi:10.1109/dtip.2016.7514837 · Cited by 10
Designing for Affordability, Application, and Performance
Johnson, A. P., Lee, J., & Veatch, B. (2012) · JPO Journal of Prosthetics and Orthotics · doi:10.1097/jpo.0b013e3182501fd7 · Cited by 9
Cited by
Biomedical applications of soft robotics
Cianchetti, M., Laschi, C., Menciassi, A., & Dario, P. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0022-y · Cited by 1,435
Self-citationWearable health devices in health care: narrative systematic review
Lu, L., Zhang, J., Xie, Y., Gao, F., Xu, S., Wu, X., & Ye, Z. (2020) · JMIR mHealth and uHealth · doi:10.2196/18907 · Cited by 701
Informal Urban Agriculture: The Secret Lives of Guerrilla Gardeners
Hardman, M., & J. Larkham, P. (2014) · Urban Agriculture · doi:10.1007/978-3-319-09534-9 · Cited by 50
EMG-based prediction of step direction for a better control of lower limb wearable devices
Anselmino, E., Mazzoni, A., & Micera, S. (2024) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2024.108305 · Cited by 15
Metadata
- Authors
- Paterno, L., Ibrahimi, M., Gruppioni, E., Menciassi, A., & Ricotti, L.
- Venue
- IEEE Transactions on Biomedical Engineering
- Published
- 2018-09
- Volume
- 65
- Issue
- 9
- Pages
- 1996-2010
- ISSN
- 0018-9294 (ISSN-L)
- 1558-2531
- OpenAlex
- W2789267097
- Cited by
- 301
- References
- 42
- FWCI
- 8.78
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.