The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Photon-Efficient Computational 3-D and Reflectivity Imaging With Single-Photon Detectors
Open accessAbstract
Capturing depth and reflectivity images at low light levels from active illumination of a scene has wide-ranging applications. Conventionally, even with detectors sensitive to individual photons, hundreds of photon detections are needed at each pixel to mitigate Poisson noise. We develop a robust method for estimating depth and reflectivity using fixed dwell time per pixel and on the order of one detected photon per pixel averaged over the scene. Our computational image formation method combines physically accurate single-photon counting statistics with exploitation of the spatial correlations present in real-world reflectivity and 3-D structure. Experiments conducted in the presence of strong background light demonstrate that our method is able to accurately recover scene depth and reflectivity, while traditional imaging methods based on maximum likelihood (ML) estimation or approximations thereof lead to noisier images. For depth, performance compares favorably to signal-independent noise removal algorithms such as median filtering or block-matching and 3-D filtering (BM3D) applied to the pixelwise ML estimate; for reflectivity, performance is similar to signal-dependent noise removal algorithms such as Poisson nonlocal sparse PCA and BM3D with variance-stabilizing transformation. Our framework increases photon efficiency 100-fold over traditional processing and also improves, somewhat, upon first-photon imaging under a total acquisition time constraint in raster-scanned operation. Thus, our new imager will be useful for rapid, low-power, and noise-tolerant active optical imaging, and its fixed dwell time will facilitate parallelization through use of a detector array.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonlinear total variation based noise removal algorithms
Rudin, L. I., Osher, S., & Fatemi, E. (1992) · Physica D: Nonlinear Phenomena · doi:10.1016/0167-2789(92)90242-f · Cited by 15,704
Fundamentals of Statistical Signal Processing: Estimation Theory
Sengijpta, S. K. (1995) · Technometrics · doi:10.1080/00401706.1995.10484391 · Cited by 11,076
Image denoising by sparse 3-D transform-domain collaborative filtering
Dabov, K., Foi, A., Katkovnik, V., & Egiazarian, K. (2007) · IEEE Transactions on Image Processing · doi:10.1109/tip.2007.901238 · Cited by 9,283
Bilateral Filtering for Gray and Color Images
Tomasi, C., & Manduchi, R. (2002) · Sixth International Conference on Computer Vision (IEEE Cat. No.98CH36271) · doi:10.1109/iccv.1998.710815 · Cited by 8,177 · cited 1×
“Each detected photon is time stamped within a time bin of duration ∆ , measuring a few picoseconds, that is much shorter than T p .”
BackgroundComputer Vision: A Modern Approach
Forsyth, D. A., & Ponce, J. (2002) · Cited by 3,739
Time-Correlated Single Photon Counting
(1984) · Elsevier eBooks · doi:10.1016/b978-0-12-524140-3.x5001-1 · Cited by 2,550
Microsoft Kinect Sensor and Its Effect
Zhang, Z. (2012) · IEEE Multimedia · doi:10.1109/mmul.2012.24 · Cited by 2,487
Picosecond superconducting single-photon optical detector
Gol’tsman, G. N., Okunev, O., Chulkova, G., Lipatov, A., Semenov, A., Smirnov, K., Voronov, B., Dzardanov, A., Williams, C., & Sobolewski, R. (2001) · Applied Physics Letters · doi:10.1063/1.1388868 · Cited by 1,597
Introduction to Probability: The Binomial And Normal Probability Distributions
(2003) · Pharmaceutical Statistics · doi:10.1201/9780203912799.ch3 · Cited by 1,208
The Photon Counting Histogram in Fluorescence Fluctuation Spectroscopy
Chen, Y., Müller, J. D., So, P. T. C., & Gratton, E. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)76912-2 · Cited by 682
Cited by
Photon-efficient imaging with a single-photon camera
Shin, D., Xu, F., Venkatraman, D., Lussana, R., Villa, F., Zappa, F., Goyal, V. K., Wong, F. N. C., & Shapiro, J. H. (2016) · Nature Communications · doi:10.1038/ncomms12046 · Cited by 325
Self-citationA Few Photons Among Many: Unmixing Signal and Noise for Photon-Efficient Active Imaging
Rapp, J., & Goyal, V. K. (2017) · IEEE Transactions on Computational Imaging · doi:10.1109/tci.2017.2706028 · Cited by 261
Self-citationSingle Photon LiDAR Compression: An Overview
Al-Shabili, A. H., Weerasooriya, H. K., Weligampola, H., Chennuri, P., Abshire, P., & Chan, S. (2023) · 2023 IEEE 66th International Midwest Symposium on Circuits and Systems (MWSCAS) · doi:10.1109/mwscas57524.2023.10405954
Metadata
- Authors
- Shin, D., Kirmani, A., Goyal, V. K., & Shapiro, J. H.
- Venue
- IEEE Transactions on Computational Imaging
- Published
- 2015-06
- Volume
- 1
- Issue
- 2
- Pages
- 112-125
- ISSN
- 2333-9403 (ISSN-L)
- 2334-0118
- OpenAlex
- W1852016712
- Cited by
- 255
- References
- 29
- FWCI
- 20.93
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Photon-Efficient Computational 3-D and Reflectivity Imaging With Single-Photon Detectors. https://app.cochat.ai/papers/10.1109/tci.2015.2453093
- The paper
- Shin, D., Kirmani, A., Goyal, V. K., & Shapiro, J. H. (2015). Photon-Efficient Computational 3-D and Reflectivity Imaging With Single-Photon Detectors. IEEE Transactions on Computational Imaging. https://doi.org/10.1109/tci.2015.2453093
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.