The DOI matches its Crossref record.
A Wireless Power Interface for Rechargeable Battery Operated Medical Implants
Abstract
Abstract—This paper describes an integrated analog front-end for wireless powering and recharging of miniature Li-ion batteries used in implantable neural recording microsystems. DC signal extraction from a wireless carrier is accomplished using Schottky barrier contact diodes with lower forward voltage drop for improved efficiency. The battery charger employs a new control loop that relaxes comparator resolution requirements, provides simultaneous operation of constant-current and constant-voltage loops, and eliminates the external current sense resistor from the charging path. The accuracy of the endof-charge detection is primarily determined by the voltage drop across matched resistors and current-sources and the offset voltage of the sense comparator. Experimental results in 0.6μm bulk CMOS technology indicate that ±1.3 % (or ±20μA) end-ofcharge accuracy can be obtained under worst-case conditions for a comparator offset voltage of ±5mV. The circuits occupy 1.735mm 2 with a power dissipation of 8.4mW when delivering a load current of 1.5mA at 4.1V (or 6.15mW) for an efficiency of 73%. I.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The lithium-ion battery: State of the art and future perspectives
Zubi, G., Dufo-López, R., Carvalho, M., & Pasaoglu, G. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2018.03.002 · Cited by 2,563
Power Approaches for Implantable Medical Devices
Amar, A., Kouki, A., & Cao, H. (2015) · Sensors · doi:10.3390/s151128889 · Cited by 432
A Study of Loosely Coupled Coils for Wireless Power Transfer
Chen, C.-J., Chu, T.-H., Lin, C.-L., & Jou, Z.-C. (2010) · IEEE Transactions on Circuits and Systems II: Express Briefs · doi:10.1109/tcsii.2010.2048403 · Cited by 306
A Review of In-Body Biotelemetry Devices: Implantables, Ingestibles, and Injectables
Kiourti, A., & Nikita, K. S. (2017) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2017.2668612 · Cited by 278
Design of a Solar-Harvesting Circuit for Batteryless Embedded Systems
Brunelli, D., Moser, C., Thiele, L., & Benini, L. (2009) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2009.2015690 · Cited by 272
Metadata
- Authors
- Li, P., & Bashirullah, R.
- Venue
- IEEE Transactions on Circuits and Systems II: Express Briefs
- Published
- 2007-10
- Volume
- 54
- Issue
- 10
- Pages
- 912-916
- ISSN
- 1057-7130 (ISSN-L)
- OpenAlex
- W2035979929
- Cited by
- 220
- References
- 0
- FWCI
- 6.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Wireless Power Interface for Rechargeable Battery Operated Medical Implants. https://app.cochat.ai/papers/10.1109/tcsii.2007.901613
- The paper
- Li, P., & Bashirullah, R. (2007). A Wireless Power Interface for Rechargeable Battery Operated Medical Implants. IEEE Transactions on Circuits and Systems II: Express Briefs. https://doi.org/10.1109/tcsii.2007.901613
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.