Simultaneous Fault Isolation and Estimation of Lithium-Ion Batteries via Synthesized Design of Luenberger and Learning Observers

Chen, Wen, Chen, Wei-Tian, Saif, Mehrdad, Li, Meng-Feng, Wu, Hai · 2014 · IEEE Transactions on Control Systems Technology

Abstract

Lithium-ion batteries possess high power, energy, and long cycle life. They are best candidates for applications on hybrid and electric vehicles. To ensure reliable operation, one of the functions in a battery management system is health monitoring in terms of fault diagnosis and estimation. The purpose of this brief is to provide a fault-diagnostic scheme that can achieve single fault isolation and estimation for a three-cell battery string subject to uncertainties. Detecting and isolating faults in systems subject to uncertainties is a challenging task due to the difficulty in distinguishing the effects of faults from uncertainties. To facilitate fault isolation, a bank of systems, each corresponding to a particular fault, are formulated by reorganizing the considered system. Each system in the bank is first transformed into two subsystems. Then, a classical Luenberger observer is designed for the first subsystem to generate a fault-detection residual. In this manner, a bank of reduced-order Luenberger observers are designed to locate a specific fault source, and thus fault isolation is achieved. Parallel to the bank of reduced-order Luenberger observers, a bank of learning observers (LOs) are also constructed to provide an estimate of the isolated fault. As a result, the synthesized design of Luenberger observers and LOs can realize simultaneous fault isolation and estimation. Parameters of an A123 battery cell are extracted via experiments, and effectiveness of the proposed design is demonstrated through simulation studies on the model of a three-cell battery string.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tcst.2013.2239296

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 163

Metadata

Authors
Chen, W., Chen, W.-T., Saif, M., Li, M.-F., & Wu, H.
Venue
IEEE Transactions on Control Systems Technology
Published
2014-01
Volume
22
Issue
1
Pages
290-298
ISSN
  • 1063-6536 (ISSN-L)
  • 1558-0865
OpenAlex
W1994870699
Cited by
163
References
1
FWCI
13.15
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Simultaneous Fault Isolation and Estimation of Lithium-Ion Batteries via Synthesized Design of Luenberger and Learning Observers. https://app.cochat.ai/papers/10.1109/tcst.2013.2239296
The paper
Chen, W., Chen, W.-T., Saif, M., Li, M.-F., & Wu, H. (2014). Simultaneous Fault Isolation and Estimation of Lithium-Ion Batteries via Synthesized Design of Luenberger and Learning Observers. IEEE Transactions on Control Systems Technology. https://doi.org/10.1109/tcst.2013.2239296

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.