Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 274

The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.

Transforming Cooling Optimization for Green Data Center via Deep Reinforcement Learning

Open access
Li, Yuanlong, Wen, Yonggang, Tao, Dacheng, Guan, Kyle·2020·IEEE Transactions on Cybernetics

Abstract

Data center (DC) plays an important role to support services, such as e-commerce and cloud computing. The resulting energy consumption from this growing market has drawn significant attention, and noticeably almost half of the energy cost is used to cool the DC to a particular temperature. It is thus an critical operational challenge to curb the cooling energy cost without sacrificing the thermal safety of a DC. The existing solutions typically follow a two-step approach, in which the system is first modeled based on expert knowledge and, thus, the operational actions are determined with heuristics and/or best practices. These approaches are often hard to generalize and might result in suboptimal performances due to intrinsic model errors for large-scale systems. In this paper, we propose optimizing the DC cooling control via the emerging deep reinforcement learning (DRL) framework. Compared to the existing approaches, our solution lends itself an end-to-end cooling control algorithm (CCA) via an off-policy offline version of the deep deterministic policy gradient (DDPG) algorithm, in which an evaluation network is trained to predict the DC energy cost along with resulting cooling effects, and a policy network is trained to gauge optimized control settings. Moreover, we introduce a de-underestimation (DUE) validation mechanism for the critic network to reduce the potential underestimation of the risk caused by neural approximation. Our proposed algorithm is evaluated on an EnergyPlus simulation platform and on a real data trace collected from the National Super Computing Centre (NSCC) of Singapore. The resulting numerical results show that the proposed CCA can achieve up to 11% cooling cost reduction on the simulation platform compared with a manually configured baseline control algorithm. In the trace-based study of conservative nature, the proposed algorithm can achieve about 15% cooling energy savings on the NSCC data trace. Our pioneering approach can shed new light on the application of DRL to optimize and automate DC operations and management, potentially revolutionizing digital infrastructure management with intelligence.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tcyb.2019.2927410

Cites

35 of 35 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 35 references

Cited by

See all 274

Metadata

Authors
Li, Y., Wen, Y., Tao, D., & Guan, K.
Venue
IEEE Transactions on Cybernetics
Published
2020-05
Volume
50
Issue
5
Pages
2002-2013
ISSN
  • 2168-2267 (ISSN-L)
  • 2168-2275
OpenAlex
W2964229770
Cited by
274
References
35
FWCI
27.18
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Transforming Cooling Optimization for Green Data Center via Deep Reinforcement Learning. https://app.cochat.ai/papers/10.1109/tcyb.2019.2927410
The paper
Li, Y., Wen, Y., Tao, D., & Guan, K. (2020). Transforming Cooling Optimization for Green Data Center via Deep Reinforcement Learning. IEEE Transactions on Cybernetics. https://doi.org/10.1109/tcyb.2019.2927410

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.